![Force Computers SPARC/CPU-5TE Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/force-computers/sparc-cpu-5te/sparc-cpu-5te_installation-manual_2317033011.webp)
FORCE COMPUTERS
Page 5
SPARC/CPU-5TE
Installation Guide
SWITCH 7
SW7-1
OFF
SCSI#1 termination for Front Panel
OFF = Automatic (When a connector is plugged
into the front panel SCSI connector, then termi-
nation is disabled. When no connector is
plugged into the front panel SCSI connector,
then termination is enabled.)
ON = disabled
SW7-2
OFF
Test Switch, must be
OFF
SWITCH 8
SW8-1
OFF
Test Switch, must be
OFF
SW8-2
ON
TRXC on Front Panel Connector for RS-232
ON=Available, OFF=Not Available
(Serial Port B)
SW8-3
ON
TRXC on Front Panel Connector for RS-232
ON=Available, OFF=Not Available
(Serial Port A)
SW8-4
OFF
TRXC +/- on Front Panel Connector for RS-422
ON=Available, OFF=Not Available
(Serial Port B)
SWITCH 9
SW9-1
ON
CTS on Front Panel Connector for RS-232 or
CTS +/- on Front Panel Connector for RS-422
ON=Available, OFF=Not Available
(Serial Port B)
SW9-2
ON
RTS on Front Panel Connector for RS-232 or
RTS +/- on Front Panel Connector for RS-422
ON=Available, OFF=Not Available
(Serial Port B)
SW9-3
ON
RTS on Front Panel Connector for RS-232 or
RTS +/- on Front Panel Connector for RS-422
ON=Available, OFF=Not Available
(Serial Port A)
SW9-4
OFF
TRXC +/- on Front Panel Connector for RS-422
ON=Available, OFF=Not Available
(Serial Port A)
Table 1: Default Switch Settings (cont.)
Diagram of Switch
Switches
Default
Setting
Function
ON
1
2
ON
1
2
3
4
ON
1
2
3
4