Chassis Layout and Interconnection
Centellis CT Series 16000 User’s Manual
Page 16
20000325 420 000 AB
3.2.1
Serial COM Port Devices
There are two serial com ports: Com 1 and Com 2. Com 1 is located on the front and rear panels of
the Centellis chassis, while Com 2 is only found on the chasis rear. Serial devices that may be at-
tached to these ports include printers, terminals, and modems. Figure 7 shows the pin configura-
tion of the COM ports. Table 3 provides the function and signal type of each COM port connector
pin.
CAUTION
!
Simultaneously using both the front and rear panel I/O connectors may cause system
damage.
Figure 7: Serial COM Connector and Pins
Table 3:
Rear COM1 & COM2 Serial Connector
Pin
Function
Descriptions
1
DCD
Data Carrier Detect
2
RxD
Receive Data
3
TxD
Transmit Data
4
DTR
Data Terminal Ready
5
GND
Ground
6
DSR
Data Send Ready
7
RTS
Request to Send
8
CTS
Clear to Send
9
RIN
Ring Indicator
Com 1 and Com 2
5
1
4
9
3
2
8
7
6