MAINTENANCE OF FORBES XTRA TUFF STORAGE WATER PURIFIER WITH SINGLE CARTRIDGE:
DOS
ü
ü
ü
ü
Important Note:
DON'TS
7
7
7
7
7
Fig. 4
Clean Sediment Filter and Particulate Filter once in 15 days with tap water
Clean Top and Bottom Container once in 15 days with tap water
Remove the cartridge to clean it (To remove cartridge put your finger at the bottom of the cartridge and lift it).
Remove plastic cage by rotating and pulling up. Fig. 4(a)
Pull the Sediment Filter in an upward direction. Fig. 4(b)
Wash the Sediment Filter (For better results you can beat this filter by holding it on one edge and slapping it against
a hard surface). Fig. 4 (c )
Clean the Carbon Block once in 15 days as follows. Fig. 4 (d)
Fill the “Bellow Pump”, provided with the unit, with water. Immerse the Carbon Block in water and close the opening
at the bottom with the thumb. Insert the “Bellow Pump” from the other end and press it like an injection. Do this
activity 3 or 4 times to backflush the Carbon Block. Fig. 4 (e)
Wash Particulate Filter under running water. Fig. 4(f)
Replace the cartridge after every 1,500 litres (10 litres per day on an average for a family of five, will give pure water
for 5 months)
0
0
For best results use input water between 10 -40 Celsius
Ensure that the stored purified water is consumed within 48 hours
Clean the Sediment Filter at regular intervals to improve water flow
1) Discard first filling of purified water on following occasions:
At the time of first use
At the time of replacement of cartridge
If not in use for 10 days after vacation
2) Always keep the cartridge in wet condition once the seal is open
Do not expose the unit to sunlight
Do not use boiled/warm water while filling the top container
Do not keep the product near a gas stove, cooking range or any hot surface
Do not open or tamper with the cartridge
Do not use strong detergent to clean the containers
•
•
•
•
•
•
•
•
•
•
•
•