10
Model No. 085-1559-4
Op
era
ti
o
n
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor area. Connect
the propane gas tank to the regulator and turn the valve on the unit to the “off” position. Brush a soap and water
mixture on all connections. Turn the gas supply on; if bubbles occur on any connection there may be a leak.
If you
smell gas or a leak is discovered turn the gas valve off, disconnect propane gas tank and do not
use the appliance until the leak is is repaired.
Pumice stones/lava rocks/LavaGlass™ could pop up and strike somebody’s face during the process of lighting this
unit; stand away from the unit for the first 20 minutes after igniting. Flame height should be a yellow/blue colour 1–7
1/2" (2.5–19 cm) in height.
Wait 5 minutes after extinguishing flame prior to placing a lid (if applicable) or protective cover on heating item.
To Light
To Extinguish
•
After assembling the gas tank, push and turn the control knob on the regulator counter-clockwise, then use a
match or lighter to light the burner.
•
To adjust the flame turn the control knob between the "HIGH" and "LOW" positions.
•
Turn the control knob clockwise to the "OFF" position.
•
Disconnect the propane tank to close off the gas supply if not using for a long period of time.
WARNING: If the lighting instructions are not followed directly a fire or explosion may occur resulting in property
damage, personal injury or death.