1. Installing the AC Cord Retaining Clip 

 
Secure the AC cord with the supplied ladder strap/retaining clip assembly to prevent accidental disconnection from the USF-212S.   
Apply before mounting on the rack. 
 
1)  Wrap the retaining clip around the AC cord.    (with the anchor of the ladder strap toward the unit.) 
2)  Insert the anchor into the hole next to the AC IN socket. 
3)  Lightly fasten the clip around the AC cord. 
4)  Plug in the power cord. 
5)  Slide the clip on the ladder strap toward the plug. 
6)  Fasten the clip tightly. 
7)  Gently pull on the AC cord to ensure it is secured. 
 
 
 

 

 

 

 
 

2. Opening the Front Panel 

The Front panel may be difficult to open if the USF frame is placed on a desk, and may be damaged the front panel if it is forced 
to open.    Perform the following steps after setting the frame in a rack. 

 
 

 

 

 
 
 
 
 

The OPEN alarm will sound every 30 seconds.    It continue sounding after 5 minutes.    In case of the power is on, complete 
the procedure in a short period of time. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3. Detaching the Front Panel 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Handle the front panel carefully so as not to bend the rails. 

 

IMPORTANT 

After the front panel is installed, the ALARM LED on the front panel will light in the following order. 
DC1 

→ DC2 → FAN → TEMP 

When the ALARM LEDs not lighting in the above order indicates the front panel has not been installed properly.    Re-install the 
front panel. 

 
 

4. Front Interior 

The slot configuration as shown below is revealed when the front panel is removed. 
 
 
 
 
 
 
 
 
 
 
 
 

No. 

Slot Type 

Description 

(1) 

Power Supply 1 slot 

Dedicated power unit is installed in this slot as standard.    Power is supplied when the 
switch is turned on. 

(2) 

Power Supply 2 slot 

Slot for redundant power supply USF-212PS.    Redundant operation available when 
optional USF-212PS is installed.    A blank panel will otherwise cover the slot. 

(3) 

Control module slot 

Fan module slot.    Enables you to monitor power supply and fan states via SNMP from 
back connector LAN A and alarm output via GPI.    LAN1 and LAN2 are not applicable. 

(4) 

Expansion slot 

Not used. 

(5) 

USF module slot 

Dedicated USF module slots. (Front USF modules) 
For details on module operation, refer to the respective operation manuals. 

 

USF-212S 

USF-212S Packing List

 

USF-212S (1 unit) 
AC Cable (1 set, including AC Cord Retaining Clip) 
CD-ROM (PDF Operation Manual) 

2) 

4) 

3) 

5) 

6) 

(1) 

(2) 

(3) 

(4) 

(5) 

The front panel rails can 
be tilted down. 

Pull out the front panel. 

 

Quick Setup Guide    

T EMP

FAN

DC 2

DC 1

ALARM

ON

POWER

USF-212

UNIVERSAL SYSTEM FRAME

LOCK

LOCK

Loosen the two thumbscrews of the front 
panel by turning them counterclockwise. 

T EMP

FAN

DC 2

DC 1

ALARM

ON

POWER

USF-212

UNIVERSAL SYSTEM FRAME

LOCK

LOCK

Pull out the front panel using the pull 
handles.    The fan stops while the 
front panel is open. 

The front panel can 
be detached by 
gently pushing both 
rails inward. 

Fully draw out the front panel. 