Precautions 

Important Safety Warnings 

[Power] 

 

Stop 

Do

  not

 place or drop  heavy  or sharp-edged objects on the power cord. A damaged 

cord  can  cause  fire  or  electrical  shock  hazards.  Regularly  check  the  power  cord  for 
excessive wear or damage to avoid possible fire / electrical hazards. 

[Circuitry Access] 

 

Stop 

Do 

not

 touch any parts / circuitry with a high heat factor. 

Capacitors can retain enough electric charge to cause mild to serious shock, even after 
the power has been disconnected. Capacitors associated with the power supply are 
especially hazardous. 

 

Hazard 

Unit should 

not

 be operated or stored with cover, panels, and / or casing removed. 

Operating the unit with circuitry exposed could result in electric shock / fire hazards or 
a unit malfunction. 

[Potential Hazards]  

 

Caution 

If  abnormal  odors  or  noises  are  noticed  coming  from  the  unit,  immediately  turn  the 
power off and disconnect the power cord to avoid potentially hazardous conditions. If 
problems  similar  to  the  above  occur,  contact  an  authorized  service  representative 

before

 attempting to operate the unit again. 

[Consumables] 

 

Caution 

Consumable items that are used in the unit must be periodically replaced. For further 
details on which parts are consumables and when they should be replaced, refer to the 
specifications  at  the  end  of  the  Operation  Manual.  Since  the  service  life  of  the 
consumables  varies  greatly  depending  on  the  environment  in  which  they  are  used, 
such items should be replaced at an early date. For details on replacing consumable 
items, contact your dealer. 

 
 

Содержание USF-111DDA-12G

Страница 1: ...USF 111DDA 12G Digital Distribution Amplifier 1st Edition OPERATION MANUAL ...

Страница 2: ...ircuitry exposed could result in electric shock fire hazards or a unit malfunction Potential Hazards Caution If abnormal odors or noises are noticed coming from the unit immediately turn the power off and disconnect the power cord to avoid potentially hazardous conditions If problems similar to the above occur contact an authorized service representative before attempting to operate the unit again...

Страница 3: ...e packing list below Check to ensure no damage has occurred during shipment If damage has occurred or items are missing inform your supplier immediately USF 111DDA 12G ITEM QTY REMARKS USF 111DDA 12G 1 USF 111DDA 12G Front Module USF 111DDA 12G Rear Module DVD ROM 1 Operation Manual PDF Screw for Rear Module Installation 4 This Product can be installed into the following frame USF 212AS USF 105AS ...

Страница 4: ... 1 2 Features 5 2 Panel Descriptions 6 2 1 Front Panel 6 2 2 Rear Panel 6 3 Switch Settings 7 4 Web GUI 8 4 1 WEB Display Information 8 4 2 syslog Functions 9 5 About SNMP 10 6 Specifications and Dimensions 11 6 1 Specifications 11 6 2 External Dimensions 11 ...

Страница 5: ... ASI and is capable of producing up to 11 outputs from 1 input 1 2 Features Installs into a USF 212AS USF 105AS frame 1 input 11 distribution outputs Supports SDI 12Gbps 3Gbps 1 5Gbps 270Mbps signals Automatic 12G 3G HD SD SDI equalizer and re clock functions Detection of input signal and identification of 12Gbps 3Gbps 1 5Gbps 270Mbps Supports DVB ASI 270Mbps signal SNMP monitoring and syslog supp...

Страница 6: ...ED Lights green when input SDI signal is 1 5G b s 5 270Mb s LED Lights green when input SDI signal is 270M b s 6 DIP switch Sets Reclock settings 7 USB connector Used to upgrade USF 111DDA 12G software Do not connect USB devices 2 2 Rear Panel USF 111DDA 12G 6 1 2 3 SDI OUT SDI OUT 4 5 SDI IN 7 8 9 10 11 Name Description SDI IN SDI signal input Accepts an SD HD 3G 12G SDI signal SDI OUT 1 11 SDI s...

Страница 7: ...g 4 OFF Do not change the setting 5 Reclock Reclock Bypass Reclock ON Normal use setting 6 ON Do not change the setting 7 OFF Do not change the setting 8 OFF Do not change the setting DS2 SW No Function Setting Factory Setting OFF ON 1 OFF Do not change the setting 2 OFF Do not change the setting 3 OFF Do not change the setting 4 OFF Do not change the setting 5 OFF Do not change the setting 6 OFF ...

Страница 8: ...111DDA 12G is installed S N Serial number of the USF 111DDA 12G MAC Address MAC address of the USF 111DDA 12G Firmware Firmware version of the USF 111DDA 12G FPGA FPGA of the USF 111DDA 12G IP Address IP address of the USF 111DDA 12G CPU Temperature Temperature of the CPU on the USF 111DDA 12G front card Video Input Displays video input status Detected Normal video input Not Detected No video inpu...

Страница 9: ...s to send syslog messages The IP address is the same as the SNMP trap address Refer to the USF 212AS USF 105AS Operation Manual for details on setting the SNMP trap address Facility Sets syslog logging facilities in Local 0 through Local 7 Header Message Sets syslog header messages up to a maximum of 63 alphanumeric characters Factory setting USF 111DDA 12G Input Video Detect Sets detection messag...

Страница 10: ...ature degree Celsius 7 INTEGER Input Video Status usf111Dda12gInputStatus 1 cannotDetect 0 not Detected 1 detected 8 INTEGER Input SDI Bit Rate usf111Dda12gSdiRate 1 cannotDetect 0 not Detected 1 sdi SD 2 sdi HD 3 sdi 3G 4 sdi 6G 5 sdi 12G 9 INTEGER Reclock Bypass Setting usf111Dda12gReclockBypass 0 reclocking 1 reclock Bypass 10 INTEGER Output 1 11 Mute usf111Dda12gOutput1Mute 0 disable 1 enable ...

Страница 11: ...I Max 100m 5C FB equivalent cable HD SDI Max 100m 5C FB equivalent cable SD SDI Max 200m 5C 2V equivalent cable SNMP SNMP Monitoring available SNMP version v2C Temperature 0 C to 40 C Humidity 30 to 90 no condensation Power 12V DC Supplied by a USF frame Power Consumption 12 7 VA 12 7W Dimensions Front module 106 W x 356 D mm Rear module 114 W x 40 7 H mm Weight 280 g Required Slots 2 Slots 6 2 Ex...

Отзывы: