5-2. Operation Mode
The jumpers in the Main and I/O cards are used to switch OUT1 between bypass and
loopthrough.
(1) MAIN CARD
MAIN CARD
Jumper Settings
Operation Mode
JP1
JP6
1-2 short
1-2 short
OPERATE
/BY-PASS
2-3 short
2-3 short
Loopthrough
*The factory default setting is OPERATE / BY-PASS.
(2) I/O CARD
I/O CARD
Jumper Settings
Operation Mode
JP1
JP2
JP3
1-2 short
1-2 short
1-2 short
OPERATE /BY-PASS
2-3 short
2-3 short
2-3 short
Loopthrough
*The factory default setting is OPERATE / BY-PASS.
*Positions 1 and 2 on JP4 to JP6 are shorted (factory default). Do not change the
settings.
The mode setting on Main card and I/O card must be the same. If settings on both cards are
different, the system does not operate properly.
JP1
JP6
1
3
3
1
JP3
JP1
JP2
1
3
1
3
1
3