UFM-15VDA
Analog Video Distribution Amplifier
UFM-18VDA
1
st
Edition - Rev.1
OPERATION
MANUAL
Страница 1: ...UFM 15VDA Analog Video Distribution Amplifier UFM 18VDA Analog Video Distribution Amplifier 1st Edition Rev 1 OPERATION MANUAL ...
Страница 2: ......
Страница 3: ... Check your received items against the packing lists below ITEM QTY REMARKS UFM 15VDA or UFM 18VDA 1 One front module One rear module Operation Manual 1 Option ITEM QTY REMARKS UFHM IFB 1 An interface Card Spacers 4 To mount on UFM 15VDA 18VDA Screws 8 To mount on UFM 15VDA 18VDA Check Check to ensure no damage has occurred during shipment If damage has occurred or items are missing inform your su...
Страница 4: ...ection 4 4 Operation 5 4 1 Front Panel Switche and Control 5 4 2 Front Panel Controls 6 4 2 1 GAIN 6 4 2 2 OPERATE BY PASS SELECT 6 5 Internal Settings 7 5 1 Jumper Locations 7 5 2 Operation Mode 8 5 3 Clamp Setting 9 6 Block Diagram 10 7 About UFHM IFB Optional 11 7 1 Installing UFHM IFB Optional 11 8 Specifications and Dimensions 13 8 1 Specifications 13 8 2 Dimensions 14 ...
Страница 5: ...FM 15VDA 8 way UFM 18VDA distribution of analog component signals is specifically designed for use with FOR A s Universal Frames Features Video gain control available on the front panel Input signal detection feature Input signal pass through loopthrough selectable for OUT1 by internal settings Clamp on off selectable for the output video signal AC coupled DC coupled output also selectable when se...
Страница 6: ...unstable 3 GAIN Used to control video gain in the range from 3dB to 3dB 4 OPERATE BY PASS indicator This indicator lights whenever the OPERATE BY PASS toggle switch is set to OPERATE 5 OPERATE BY PASS toggle switch Setting Indicator Description OPERATE Bottom position Lit Outputs the processed signals BY PASS Top position Unlit Bypasses input video signal to the VIDEO OUT 1 connector 6 INTERFACE T...
Страница 7: ... off or the OPERATE BY PASS toggle switch is set to BY PASS This connector can be also used as a loopthrough connector VIDEO IN signal loopthrough by internal settings 3 VIDEO OUT 2 3 4 5 UFM 15VDA Used to output video signals 4 VIDEO OUT 2 3 4 5 6 7 8 UFM 18VDA Used to output video signals UFM 15VDA UFM 18VDA 1 2 3 VIDEO IN 1 BY PASS THRU VIDEO OUT UFM 15VDA 2 3 4 5 1 4 2 1 BY PASS VIDEO IN THRU ...
Страница 8: ...ill be installing 1 OPERATE BY PASS mode 2 Loopthrough mode VIDEO IN is high impedance when in loopthrough mode The last device in the chain should be terminated with 75Ω Composite signal VIDEO IN OUT 1 BY PASS OUT 2 OUT 3 OUT 4 UFM 15VDA UFM 18VDA UF 106A or UF 112 universal frame OUT 5 Composite signal OUT 6 OUT 7 OUT 8 Composite signal VIDEO IN OUT 2 OUT 3 OUT 4 UFM 15VDA UFM 18VDA UF 106A or U...
Страница 9: ...ls Switch and Control Default Setting Refer to 1 GAIN 4 2 1 2 BY PASS OPERATE OPERATE Bottom position 4 2 2 See section 5 2 Operation Mode for the loopthrough settings See section 5 3 Clamp Setting for the clamp settings UFM 15VDA UFM 18VDA POWER INPUT UFM 15VDA GAIN BY PASS OPERATE OPTION INTERFACE 1 2 POWER INPUT UFM 18VDA GAIN BY PASS OPERATE OPTION INTERFACE ...
Страница 10: ...ATE The OPERATE BY PASS indicator lights up when set to OPERATE IMPORTANT The OPERATE BY PASS switch is disabled in loopthrough mode regardless of the indicator status See section 5 2 Operation Mode for the loopthrough settings UFM 15VDA UFM 18VDA UFM 15VDA UFM 18VDA POWER INPUT UFM 15VDA GAIN BY PASS OPERATE OPTION INTERFACE POWER INPUT UFM 18VDA GAIN BY PASS OPERATE OPTION INTERFACE POWER INPUT ...
Страница 11: ...pers on the front module and rear module of the UFM 15VDA 18VDA Switch settings must be made prior to installing any module to the UF 106A UF 112 universal frame 5 1 Jumper Locations Jumper MAIN CARD JP1 JP6 SW 1 AC DC SW 2 CLAMP ON CLAMP OFF I O CARD JP3 JP1 JP2 Jumper JP5 JP4 JP6 ...
Страница 12: ...PERATE BY PASS 2 I O CARD I O CARD Jumper Settings Operation Mode JP1 JP2 JP3 1 2 short 1 2 short 1 2 short OPERATE BY PASS 2 3 short 2 3 short 2 3 short Loopthrough The factory default setting is OPERATE BY PASS Positions 1 and 2 on JP4 to JP6 are shorted factory default Do not change the settings The mode setting on Main card and I O card must be the same If settings on both cards are different ...
Страница 13: ...etting Coupling Clamp SW2 SW1 CLAMP OFF position AC position AC coupled default DC position DC coupled CLAMP ON position AC position DC clamp DC position The factory default settings AC SW1 CLAMP OFF SW2 Positions 1 and 2 on JP4 to JP6 are shorted factory default Do not change the settings SW2 CLAMP ON CLAMP OFF SW1 AC DC ...
Страница 14: ... Block Diagram A block diagram of UFM 15VDA 18VDA is shown below VIDEO IN OUT 1 BY PASS OUT 2 OUT 3 OUT 4 OUT 5 Gain Adjust Input Detection Clamp Setting BY PASS RELAY OUT 6 OUT 7 OUT 8 UFM 15VDA UFM 18VDA ...
Страница 15: ...he dipswitch settings are factory configured UFHM IFB DIP SW S1 Settings UFM 15VDA UFHM IFB Switch S1 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 OFF ON OFF OFF OFF OFF OFF OFF UFHM IFB DIP SW S1 Settings UFM 18VDA UFHM IFB Switch S1 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 ON ON OFF OFF OFF OFF OFF OFF 7 1 Installing UFHM IFB Optional If you purchased the UFHM IFB separately first mount the UFHM IFB on the UFM 15 18V...
Страница 16: ...removed shield board to the original position and secure it with the six screws removed in step 1 4 With careful attention paid to the connector positions mount the UFHM IFB on the UFM 15 18VDA front module 5 Secure the UFHM IFB using the supplied four screws marked with white circles If your UFHM IFB is already installed at the factory these steps are not necessary 4 ...
Страница 17: ...gh mode Frequency response 100kHz 12MHz within 0 3dB DG DP 0 5 0 5 APL 50 Gain range Input signal gain control in the range from 3 0dB to 3 0dB Clamp Clamp ON OFF internally selectable AC coupled DC coupled selectable when set to CLAMP OFF Temperature 10 C 40 C Humidity 30 90 no condensation Power 12VDC to 24VDC supplied with universal frame Power consumption Approx 242mA at 12VDC 121mA at 24VDA W...
Страница 18: ...40 106 108 5 UFM 18VDA VIDEO OUT THRU 1 BY PASS VIDEO IN S No 2 3 4 5 8 7 6 UFM 18VDA POWER INPUT GAIN BY PASS OPERATE OPTION INTERFACE 303 13 5 66 1 20 POWER 106 108 5 UFM 15VDA VIDEO OUT THRU VIDEO IN 1 BY PASS 2 3 4 5 UFM 15VDA INPUT GAIN BY PASS OPERATE OPTION INTERFACE ...
Страница 19: ...en the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the in...
Страница 20: ...Fax 1 352 378 5320 FOR A Corporation of Canada 346A Queen Street West Toronto Ontario M5V 2A2 Canada Phone 1 416 977 0343 Fax 1 416 977 0657 FOR A Latin America the Caribbean 5200 Blue lagoon Drive Suite 760 Miami FL 33126 USA Phone 1 305 931 1700 Fax 1 305 264 7890 FOR A UK Limited UNIT C71 Barwell Business Park Leatherhead Road Chessington Surrey KT9 2NY UK Phone 44 0 20 8391 7979 Fax 44 0 20 83...