![FOR-A MV-42HSA Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/for-a/mv-42hsa/mv-42hsa_quick-setup-manual_2316737002.webp)
MV42HSA_SETUPGUIDE-E-3.DOCX
MV-42HSA
Quick Setup Guide
Connection
Setup Procedure
1) Apply DC power to the MV-42HSA using an AC adapter.
* The unit turns on when the power is applied. There is no ON/OFF switch.
2) Connect an SDI and/or DVI monitor.
3) Connect signal source devices, such as video cameras, to the HD/SD-SDI IN and/or ANALOG COMPOSITE IN connectors.
* To use analog composite signals, go to [SYSTEM 2/2]>[INPUT] in the menu and change input source settings.
4) Connect a PC to be used for remote control using an RS-232C straight cable.
5) Connect a switcher, etc. for tally inputs.
6) Connect a PC to be used for remote control to the MV-42HSA LAN connector using a LAN cable.
* Use a crossover LAN cable when connecting the MV-42HSA directly to a PC. Use a straight LAN cable when connecting the
MV-42HSA and PC through a hub.
7) Input a BB or tri-level sync signal.
8) Input a time code to be used for Time display.
When Nothing Appears on the Monitor!
If the newly connected monitor does not support the current output format and cannot display anything on the monitor screen, you can
change output formats and have it display the output format on screen using a format changeover feature. The factory default output
format is 1080/59.94i.
Turning the unit power on while pressing a button ( 1 through 4) starts the system in the corresponding format, which is displayed on
screen. The MV-42HSA is then set to always output in the selected format.
Button
Output format
Monitor display
1
1080/59.94i
1080/59.94i OUTPUT
2
1080/50i
1080/50i OUTPUT
3
720/59.94p
720/59.94p OUTPUT
4
720/50p
720/50p OUTPUT
Front Panel
To Display in Full Screen Mode
To display your desired channel in Full Screen mode, press the corresponding button from among buttons 1 to 4 . For instance, to
view channel 3 in Full Screen, press button 3 .
* A black screen is shown for any channel without an input signal.
To Sequentially Display Channels in Full Screen
The AUTO button initiates sequential display of channels 1 through 4 in Full Screen mode. Channels without an input signal will be
skipped. Press the 1 , 2 , 3 , 4 , or MULTI button to stop sequential display.
* The switching interval can be set in the AUTO SEQUENCE TIME menu.
To Display a Multi-channel screen
Press the MULTI button to display a multi-channel screen.
* A black screen is shown for any channel without an input signal.
* Select quad, Right-left split-screen, or 4K down-converter screen in the [MULTI CH SCREEN SETUP] > [DISPLAY TYPE] menu or
via the command protocol.
Precautions
- Operate the unit
only
at the specified supply voltage.
-
Ensure
the unit is properly grounded at all times.
-
Ensure
the power cord and connectors are firmly connected.
-
Do not
access circuitry with power applied to the unit.
- Unit
should not
be operated or stored with the cover, panels,
and/or casing removed.
- Unit s
hould not
be operated or stored in a humid, dusty, etc.
environment. Doing so could result in fire or electrical shock.
-
Do not
allow fluids, metal fragments, or any other foreign
objects to enter the unit. If foreign matter does enter the unit,
turn the power off and disconnect the power cord immediately.
Remove the material or contact your authorized service
representative.
- If you notice any strange smells or noises coming from the unit,
turn the power off immediately, disconnect the power cord,
then contact your authorized service representative.
Packing list
MV-42HSA:1, CD-ROM:1, Quick Setup Guide: 1 (This guide)
Option items:
MV-42AI (installed), MV-42IF/IFA (installed), AC adapter, Rack mount bracket set
https://www.for-a.com/
You can download manuals and other documents by registering your email address.
Use SDI and DVI monitors that
support 1920 x 1080 (59.94 or 50)
interlaced and/or 1280 x 720 (59.94
or 50) progressive video signals.
RS - 232C
1
1
2
2
3
3
4
4
HD / SD - SDI IN
ANALOG COMPOSITE IN
REF IN
LTC IN
HD-SDI OUT
DVI-D OUT
LAN
REMOTE / TALLY
DC12V IN
SER. NO.
AC cord
AC adaptor
5
ANALOG COMPOSITE IN (1-4)
(Connect video cameras, etc. to
input analog composite signals.)
PC
LAN
(Connect a PC for remote control
using command protocols.)
LAN
REF IN
(Input an external
reference signal to
synchronize HD-
SDI signals.)
LTC IN
(Input a time code
to synchronize the
time display.)
HD/SD-SDI IN (1-4)
(Connect video cameras, etc. to input
3G/HD/SD-SDI signals. Auto format detection)
HD-SDI OUT
(Connect an SDI
monitor to output
video/audio signals.)
DVI-D OUT
(Connect a DVI monitor
to output video signals.)
REMOTE/TALLY
(Connect a
production or routing
switcher for (red and
green) tally inputs
and remote control.
RS-232C
(Connect a PC for
title settings and
remote control using
command protocols.)
PC
3
7
6
2
2
3
1
8
4
MV-42IF/IFA
MV-42AI
Optional
品
Optional
品
Optional
品
Optional
品
Secure the AC adaptor
DC cord with the
attached DC cord
retaining clip.
POWER LED
AUTO button
(Sequentially displays
channels 1 through 4 in
full screen.)
1
~
4 (Full screen) buttons
(Each button displays the
corresponding channel
signal in full screen.)
MULTI button
(Changes display mode to
multi-channel screen.)
Arrow buttons
(Works as arrow buttons while
a menu is open to navigate or
change menu values.)
MENU button
(Hold down at least 2
seconds to access menus.)
ENTER button
(Used to confirm settings or go to submenus
for menu operation. Pressing an arrow button
while holding down the ENTER button allows
to change values by 10 or 100.)
MULTI VIEWER
FULL SCREEN
POWER AUTO
1
2
3
4
MULTI
MENU
ENTER
MV-42HSA