9
2-2. MV-12SDO / 12PCO
Follow the procedure described as below for MV-12SDO and MV-12PCO units.
The installable slot is OUTPUT SLOT.
1. Same procedure as that of Sec. 2-1
. “MV-12SDI / 12PCI / 12IF” Step 1.
2. When optional card(s) is (are) installed into INPUT SLOT B and/or IF SLOT, they may
interfere with the installation of an optional card in OUTPUT SLOT, in which case the optional
card(s) should be uninstalled.
a. Detach the installed optional card or blank panel of INPUT SLOT B by removing the two
M3x6 Pan screws on the rear panel and the two M3x6 SEMS screws on the card and lift
the card up at a right angle, to not damage any connectors.
Type of the rear panel screw is different from the ones fastening the top plate, so do not
mix the screws.
b. When an MV-12IF is installed, un-install the unit following the above procedure.
When a blank panel is on the IF slot, it does not need to be detached.
3. Detach the OUTPUT SLOT blank panel.
a. Detach the 2 screws (M3x6 Pan head).
Type of the blank panel screw is different from the ones fastening the top plate, so do not
mix the screws.
1
2
3
4
LAN
L/R
HDMI OUTPUT
HDMI INPUT
4
3
2
1
3G/HD-SDI
OUTPUT
AC100-240V 50/60Hz IN
ALARM OUT
AUDIO OUT
3G/HD/SD-SDI,COMPOSITE INPUT
4. Detach the blank panel of the fan slot for the OUTPUT SLOT.
a. Detach the 2 screws (M3x6 Pan head) to remove the blank panel.