12
3. [MFR-6100] I/ O Card Installation / Replacement
3-1. Checking Installation Slots
When installing both MFR-9SDI and MFR-9SDI12GA cards, there are installation restrictions.
To properly function cards, locate the right place for installing cards. If these cards are installed in
wrong slots, BNC cables cannot be connected or BNC connectors or BNC cables may be damaged.
Check the card installation status. Follow the procedure below.
(1) Unfasten four fixing screws on the front panel and detach the front panel.
(2) Open the [STATUS > SLOT] menu in the Menu display. (See Sec. 4-1-4. “STATUS > SLOT”
in the MFR-6100 Operation Manual for details.)
The illustration below shows the right place for installing these cards.
◆
When installing into top slots (INPUT1 to 8 (No.1 to 4, 13 to 16))
◆
When installing into bottom slots (INPUT 9 to 16 (No. 17 to 20, 29 to 32))
Install as shown below
Do not install
Front Panel view
Blank panel
9SDI
9SDI12GA
Blank panel
9SDI12GA
9SDI
9SDI
9SDI12GA
Front Panel view
9SDI
9SDI12GA
Install as shown below
Front Panel view
9SDI
Blank panel
9SDI
9SDI12GA
9SDI12GA
9SDI
9SDI12GA
Blank panel
Front Panel view
9SDI
9SDI12GA
Do not install