5. LOCK and INHIBIT
LOCK and INHIBIT functions are used to prevent operation mistakes. LOCK function disables AUX unit
operation and INHIBIT function disables selected buttons or rotary encoder. (INHIBIT function is
available only on HVS-AUX16D)
5-1. LOCK (Front Panel Lock)
The LOCK function allows you to disable AUX Unit front panel control.
To disable front panel operation:
Press and hold LOCK down for 3 or more seconds until the button blinks.
The LOCK indicator also blinks red and panel control is disabled.
To unlock the front panel:
Press and hold LOCK down for 3 or more seconds until the button turns off.
The LOCK indicator also turns off and panel control is enabled.
5-2. INHIBIT (HVS-AUX16D)
Procedure to inhibit Button no. 1 and the rotary encoder operation is explained as an example.
(1) Press Button 1 while holding down INHIBIT.
(2) Press the rotary encoder while holding down INHIBIT.
(3)
Press and hold down
INHIBIT. INHIBIT blinks and
INHIBIT
function is enabled.
Button 1 is disabled. If pressed, the button LCD
displays “x”.
The rotary encoder operation is disabled. If operated, INHIBIT blinks.
To release INHIBIT function,
press and hold down
INHIBIT to turn off the button.
To release INHIBIT settings on Button 1 and the rotary encoder, repeat steps (1) and (2).