Fook Tin Technologies FM-632ISLE Скачать руководство пользователя страница 4

3. If the selected memory is occupied, the screen then 

displays the height for 3 seconds, then follow steps 4-5 in 
the section of Select Memory Location.

B. To Fast-Recall Settings from Memory

  

1. Press ▲or ▼ to select the memory location.  

2. If the selected memory is free, no numbers will be 
    displayed

 

(Fig.10).

6

2. If the selected memory location is occupied, it will display 
    "       " on the left of the memory (Fig.6). 

3. Press 

      

 to store the settings to the desired memory 

location,  then height setting value will display on LCD 

(Fig.7), then press ▲ or ▼ key to adjust the height, press    
to confirm (Fig.8). 

4. The moving zero will display on LCD when the height value 
    is confirmed, then “0.0kg” will be display on LCD. 

5. Step onto the scale & stand still while the weight is locked, 
    BMI calculation value will display on LCD (Fig.9).

Fig.6

Fig.7

Fig.8

Fig.9

Weighing With BMI Functions With Memory 

 

The scale features 5 personal memory settings. This allows 
5 users to store and recall their own height.  

A

  

Select Memory Location

  

1. Press ▲ or ▼ to toggle between memory locations “1”, “2”, 

    “3” “4”  “5”, then press 

       

 to confirm the location

 

(Fig.5).

Fig.5

Fig.10

Weight: 82.4KG

Weight: 82.4KG

Height: 181cm

BMI: 25.2

7

PROBLEM-SOLVING

  

1.  Display 

Err0

 Initialization error.  

     Step off the scale. Press lightly on the scale platform to re-initialize the scale, the  
     display shows           and then turns off. The scale is ready for use again.  

2.  Display 

Err1

 Instability error.  

 Repeat measurement again, stand still while computation is in process.  

3.  Display 

Err2

 Overload warning.  

     Remove the weight immediately, otherwise permanent damage to the scale will 
     occur. 

RS232 Output

1.  Always is on after power up
2.  The default setting of the baud rate is 9600,8,n,1.
3.  Once the weight is locked, the weight value is transmitted out via rs232. Or At 
     BMI mode, the weight value and BMI value is transmitted out via rs232.

To Clear Memory

  

1. Follow steps 1-3 in the section of To Fast-Recall Memory.  

2. If the selected memory is occupied, press and hold Clear key  
    will clear height memory value.

Weight Value RS232 Output Format

BMI Value RS232 Output Format

CARE AND MAINTENANCE

  

1.  Do not disassemble the product other than replacing the battery; it contains no user 
     serviceable parts. Damage to the unit may occur as a result of improper handling.  
2.  Remove battery when the unit is not used for a prolonged period of time.
3.  Clean the unit after use with a lightly dampened cloth. Do not use solvents or 
     immerse the unit in water.  
4.  Avoid excessive impact or vibration to the unit, such as dropping the product onto 

     the floor. 

Отзывы: