4b.
Mount the control box on the wall. Drill two 1/8"
(3mm) holes as shown, and push drywall anchors
into each hole. Secure the control box to the wall
with the drywall screws.
5. Connect The Sensor Cable
Plug the sensor cable from the faucet into the
control box to activate the infrared sensor.
6. Water Pipe Connections
Connect the incoming water supply line to the
control box, at the connection marked Inlet. Thread
on the swivel nut to the hose by hand. Tighten with
a wrench.
Connect the faucet hose to the control box, at the
connection marked Outlet.
Water Supply
Outlet
Water Supply
Inlet
Please wait approximately 60 seconds after
connecting the sensor cable for sensor calibration to
complete and to begin using the faucet.
or
Temp. Control Thermostatic Mixer
Many automatic faucets do not have hot & cold
handles to adjust the water temperature coming
out of the spout, and normally installed to a single
water supply only. This valve is used for automatic
faucet to mix hot and cold water and to control
water temperature. Normally it would be mounted
under the sink with required temperature set.
Working Pressure: 0.05MPa-0.5MPa
Cold Water Temp: 0°C
Hot Water Temp: 85°C
Outlet Flow Rate: 20m
3
/h
Cold Water in
NPS male G1/2
Mixer Water out
NPS female G1/2
Hot Water in
NPS male G1/2
Fontana Sensor Faucets
©
Fontana Sensor Faucet
Customer Service: 800-684-4489
fontanasensorfaucets.com