VIEW IP SETTING
Touch the
icon to display the IP setting interface.
VIEWING THE IP ADDRESS
The interface shown in Figure 8 appears. User can view the IP address, MASK, and the gateway address.
Figure 8 Viewing the IP address information
TROUBLESHOOTING
The following list of causes and corrective actions can be referenced when attempting to troubleshoot issues
with the ZS-200M:
Issues
Possible Causes
Corrective Action
Nothing
displays on the
screen
A power failure has occurred or an
incorrect power adapter is being used
Replace the power adapter.
Note: The ZS-200M uses a DC 12V/1A power
adapter.
The ZS-200M is in the standby state
Press any key to “wake up” the screen so
it can be used.
The ZS-200M failure
Contact the appropriate equipment
vendor for timely maintenance.
Cannot
perform
broadcasting
Not familiar with the operation of the
equipment
Please carefully read the Operation
Manual.
Incorrect or invalid broadcasting ZS-
200M system configuration
Double check the configuration settings
of the ZS-200M functions through the
system configuration software
Cannot use
the full
Incorrect or invalid ZS-200M system
configuration
Double check the ZS-200M configuration
settings through the system configuration
software
duplex
intercom
function
software
Opposite party is not online
The opposite party must be online to
initiate the full duplex intercom function
No sound
when
speaking
Incorrect paging operation performed
Follow the paging directions in section 3,
ZS200M Operations Guide
The volume of the ZS-200M is very low
Adjust the volume of the microphone.
No sound
when
monitoring
The volume of the monitoring
loudspeaker is very low
Adjust the volume of the monitoring
loudspeaker