EN
- 8 -
COMMUNICATION PROTOCOL RS-232
To control the equipment via the RS-232 port it is recommended that you use Windows Hyperterminal or
similar applications, using a straight-through RS-232 cable for connection. The program must be configured
using the following values:
- Select the corresponding COM port, click on Configure and set the following values:
- Bits per second: 9600
- Data bits: 8
- Parity: none
- Stop bits: 1
- Flow control: none
- It is recommended that you set the following values in File/Properties/Configuration/Configuration ASCII.
Send line ends with line feeds
Echo typed characters locally
Append line feeds to incoming line ends
COMMAND
COMMAND
FUNCTION
COMMAND
FUNCTION
MONITOR
FF 06 8D 93
ON
Assign MONITOR
to ZONE 1
FF 06 8F 95
ON
Assign MONITOR
to ZONE 3
FF 06 0D 13
OFF
FF 06 0F 15
OFF
FF 06 8E 94
ON
Assign MONITOR
to ZONE 2
FF 06 90 96
ON
Assign MONITOR
to ZONE 4
FF 06 0E 14
OFF
FF 06 10 16
OFF