19
2.4.
Operating data
BTFS 24
Fuel
Max. heat input
(kW)
Min. heat
output
(kW)
Max. heat
output
(kW)
Gas mains
pressure (mbar)
Nozzle
diameter
(mm)
Burner pressure
(mbar)
min
max
Methane gas G20
25.5
9.5
23.8
20
1.25
2.5
13.5
Butane gas G30
25.5
9.5
23.8
29
0.77
4.2
27.0
Propane gas G31
25.5
9.5
23.8
37
0.77
5.5
35.7
Table 4
Instantaneous DHW supply ΔT 45 K = 7.6 l/min
Instantaneous DHW supply ΔT 40 K = 8.5 l/min
Instantaneous DHW supply ΔT 35 K = 9.7 l/min
Instantaneous DHW supply ΔT 30 K = 11.4 l/min
Instantaneous DHW supply ΔT 25 K = 13.6 l/miin
BTFS 28
Fuel
Max. heat input
(kW)
Min. heat
output
(kW)
Max. heat
output
(kW)
Gas mains
pressure (mbar)
Nozzle
diameter
(mm)
Burner pressure
(mbar)
min
max
Methane gas G20
30.5
10.0
28.4
20
1.35
1.3
11.5
Butane gas G30
30.5
10.0
28.4
29
0.80
3.5
28.5
Propane gas G31
30.5
10.0
28.4
37
0.80
4.5
33.0
Table 5
Instantaneous DHW supply ΔT 45 K = 9.0 l/min
Instantaneous DHW supply ΔT 40 K = 10.2 l/min
Instantaneous DHW supply ΔT 35 K = 11.6 l/min
Instantaneous DHW supply ΔT 30 K = 13.6 l/min
Instantaneous DHW supply ΔT 25 K = 16.3 l/min
BTFS 32
Fuel
Max. heat input
(kW)
Min. heat
output
(kW)
Max. heat
output
(kW)
Gas mains
pressure (mbar)
Nozzle
diameter
(mm)
Burner pressure
(mbar)
min
max
Methane gas G20
33.6
12.2
31.3
20
1.40
1.7
9.2
Butane gas G30
33.6
12.2
31.3
29
0.78
4.1
28.2
Propane gas G31
33.6
12.2
31.3
37
0.78
5.5
34.8
Table 6
Instantaneous DHW supply ΔT 45 K = 10.0 l/min
Instantaneous DHW supply ΔT 40 K = 11.2 l/min
Instantaneous DHW supply ΔT 35 K = 12.8 l/min
Instantaneous DHW supply ΔT 30 K = 15.0 l/min
Instantaneous DHW supply ΔT 25 K = 17.9 l/min
Burner pressures must be checked after 3 minutes of boiler operation.
BTN 24
Fuel
Max. heat input
(kW)
Min. heat
output
(kW)
Max. heat
output
(kW)
Gas mains
pressure (mbar)
Nozzle
diameter
(mm)
Burner pressure
(mbar)
min
max
Methane gas G20
25.7
9.85
23.31
20
1.25
2.5
13.0
Butane gas G30
25.7
9.85
23.31
29
0.77
5.3
27.0
Propane gas G31
25.7
9.85
23.31
37
0.77
6.6
35.5
Table 3
Instantaneous DHW supply ΔT 45 K = 7.4 l/min
Instantaneous DHW supply ΔT 40 K = 8.4 l/min
Instantaneous DHW supply ΔT 35 K = 9.5 l/min
Instantaneous DHW supply ΔT 30 K = 11.1 l/min
Instantaneous DHW supply ΔT 25 K = 13.4 l/min
Note: DHW supply refers to instantaneous production.