This manual contains data and information for both the user and the installer.

Specifically, the user must pay attention to the chapters: General warnings and safety devices, Control panel and Use of the appliance.

General warnings and safety devices

The instruction manual is an integral part of the product and must 
therefore be carefully stored and always accompany the appliance; 

in case of loss or damage, request another copy from the Technical 

Service Centre.

  The appliance must be used as intended by the manufactur-

er. contractual and non-contractual liability is excluded for 

damage to persons, animals or property, due to installation, 

adjustment and maintenance errors or improper use

 

The installation, service and user manual constitutes an inte

-

gral part as well as essential equipment of the water heater 

and must be retained for the entire period of use and read 

carefully as it contains all the information and warnings re-

garding safety during installation, operation and maintenance, 

which must be respected. In the case of transfer of the ap-

pliance  to  any  other  user,  ensure  it  is  accompanied  by  the 
installation, service and user manual

  Installation of the appliance and any other intervention of ser-

vice and maintenance must be performed by qualified person

-

nel in compliance with the legislation in force and subsequent 

updates

  For installation it is advisable to use specialist personnel

  Failure to comply with the recommendations of this user 

manual and failure to adhere to the instructions included 

therein by installers and by the user will invalidate any future 
warranty claim

 

The  safety  or  automatic  adjustment  devices  must  only, 

throughout the life of the system, be altered by the manufac

-

turer

  This appliance is used to produce hot water.  It must there-

fore be connected to a domestic hot water distribution net-

work, according to its performance and power

 

In  case  of  leakages  of  water,  close  the  water  supply  and 

promptly notify the qualified personnel of the Technical Ser

-

vice Centre

 

In case of prolonged absence, shut off the gas supply. Where 

the risk of freezing is anticipated, empty the water heater of 

the water contained therein

 

In case of failure and/or malfunction of the appliance, switch 

it off and do not attempt any kind of repair or direct action

  Maintenance must be performed at least once a year: sched-

uling this with the Technical Support Centre will avoid wast-

ing time and money

A number of symbols are used In some parts of the manual:

 

ATTENTION

 = for actions that require particular care and adequate preparation

 

PROHIBITED

 = for actions that MUST NOT be performed

  At the end of its life span the product must not be disposed 

of as solid urban waste but must be removed to a recycling 

centre

 

The casing can reach high temperatures in the burner area, 

with the risk of burns in the event of contact.

Use of the appliance requires strict adherence to certain fundamental 

safety rules:

  Do not use the appliance for purposes other than those for 

which it was intended

 

Under  no  circumstances  cover  with  rags,  papers  or  other 

material the inlet or dissipation grids and the ventilation shaft 

of the room where the appliance is installed

 

Where the smell of gas is perceived, refrain from using any 

electrical switches, telephones or any other object that could 

cause sparks. Ventilate the room by opening doors and win-

dows and close the main gas valve

  Do not place objects on the appliance

 

Do not leave containers or flammable substances in the room 

where the appliance is installed

  Any attempt to carry out a repair in case of failure and/or 

malfunction of the appliance is inadvisable

  The use of this appliance by children or inexperienced per-

sons is not recommended

  It is forbidden to intervene on sealed elements

Содержание Lipari Pro Tfs 11i

Страница 1: ...IST 03 C 1208 01 GAS WATER HEATER INSTALLATION USE AND MAINTENANCE LIPARI PRO TFS 11i 14i EN Translation of the original instructions in Italian...

Страница 2: ...he right to increase the temperature and to the left to decrease it temperature between 37 and 60 C POWER OFF Press and hold the on off button As soon as the symbols begin to flash release the button...

Страница 3: ...HEET Fondital Lipari Pro Tfs 11i Lipari Pro Tfs 14i 2 Declared load profile M XL 4 Internal sound power level dB A 51 50 6 Water heating energy efficiency class A A Water heating energy efficiency 69...

Страница 4: ...there fore be connected to a domestic hot water distribution net work according to its performance and power In case of leakages of water close the water supply and promptly notify the qualified perso...

Страница 5: ...gets out to the final user The special burner cools the flame and check the airflow necessary for the combustion set up cooled flames avoiding the loss of ther mal efficiency generating an optimal com...

Страница 6: ...tallation size Measurements in mm AC Hot water G Gas AF Cold water 52 52 100 100 8 5 7 0 92 5 100 100 92 5 7 0 8 5 11i 14i 304 1 7 6 1 9 6 2 8 6 4 1 6 5 8 AC G AF G H2 O 70 4 85 222 238 6 1 7 AC G AF...

Страница 7: ...able mechanism that com plieswith the applicable regulations Wall mounting Precautions Do not install this appliance in a room with an ambient atmosphere containing fatty and or corrosive dust or va p...

Страница 8: ...nce with the regulations in force Before installing the appliance blow into the gas pipe in order to remove any residue Connect the water heater to the gas pipe of the internal system and fit upstream...

Страница 9: ...uration combustion product exhaust is outside the home through concentric pipes while air intake is in the room where the appliance is installed TYPE C Horizontal coaxial exhausts In this configuratio...

Страница 10: ...l exhausts Lipari ProTfs 14i up to 1 45 from 1 to 1 9 47 from 1 9 to 3 7 not installed TYPE C Vertical coaxial exhausts Lipari ProTfs 11i up to 2 43 1 m 1 4 m from 2 to 3 7 45 from 3 7 to 6 7 not inst...

Страница 11: ...o 102 Pa Flangia fumo 46 mm 45 Pa Flangia fumo 44 mm 24 Pa Flange flues not installed Flange flues 45 mm Flange flues 43 mm Lipari ProTfs 11i 0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35 40 45 50 55 60...

Страница 12: ...entric or separate where combustion product exhaust is in one and combustion air intake in the other The outlets placed rather close to be subject to similar wind conditions C52 C52x Fume exhaust and...

Страница 13: ...water heater h h Open a hot water valve to full capacity Check the gas pressure referring to the values indicated in the data table If the pressure is higher than 15 mbar calibrate the gas valve Duri...

Страница 14: ...MTN 1 LPG h h If selected LPG gas the gas setted is propane If is necessary to set butane gas set parameter 13 to 2 h h To store the value press the reset button h h At the end of the procedure the a...

Страница 15: ...ter flow limiter l min 8 10 Continuous intake capacity T 35 K l min 8 10 Minimum ignition flow l min 2 2 Selectable water temperature C 37 60 37 60 Minimum pressure bar 0 13 0 13 Maximum pressure bar...

Страница 16: ...e necessary checks proceed with the following operations Electrically power the water heater Open the gas valve installed upstream of the water heater Open the water tap at the bottom of the water hea...

Страница 17: ...pear on the display release the button The appliance automatically restarts If the fault persists request the assistance of a qualified technician Permanent shutdown Domestic water NTC fault alarm IN...

Страница 18: ...consecutive times alarm Request the assistance of a qualified technician Temporary shutdown Button alarm This is displayed when you keep pressed the button for more than 30 seconds once the button is...

Страница 19: ...t fig 21 button for about 10 seconds the display symbols start to flash First the symbol is displayed and then the symbol h h Release the reset button h h Enter the code by turning the knob and confir...

Страница 20: ...oint 0 1 0 09 Ignition power 0 40 40 13 LPG gas type 1 propane 2 butane 1 2 1 17 Complete or partial calibration 0 100 0 18 Domestic hot water modulation with flow meter 0 modulation without flow mete...

Страница 21: ...button h h Press the reset button until MENU flashing release the button the display shows h h Press again the reset button until the display shows MENU flashing release the button the display shows t...

Страница 22: ...ectors Removing the gas valve Fig 28 Remove the casing by referring to the specific paragraph Unscrew the screws that secure the panel to the bottom shelf Remove the panel without disconnecting the wi...

Страница 23: ...cts whether it be new or old l Force majeure due to particular weather events e g earthquakes floods lightning storms excessive precipitation etc as well as fires vandalism theft stray currents and or...

Страница 24: ...Fax 39 0365 878 576 e mail info fondital it www fondital com The manufacturer reserves the right to modify his her products as deemed necessary without altering the basic characteristics of the produ...