IST 03 C 1208 - 01

GAS WATER HEATER

INSTALLATION, USE AND MAINTENANCE

LIPARI PRO TFS

11i - 14i

EN

Translation of the original 

instructions (in Italian)

Содержание Lipari Pro Tfs 11i

Страница 1: ...IST 03 C 1208 01 GAS WATER HEATER INSTALLATION USE AND MAINTENANCE LIPARI PRO TFS 11i 14i EN Translation of the original instructions in Italian...

Страница 2: ...he right to increase the temperature and to the left to decrease it temperature between 37 and 60 C POWER OFF Press and hold the on off button As soon as the symbols begin to flash release the button...

Страница 3: ...HEET Fondital Lipari Pro Tfs 11i Lipari Pro Tfs 14i 2 Declared load profile M XL 4 Internal sound power level dB A 51 50 6 Water heating energy efficiency class A A Water heating energy efficiency 69...

Страница 4: ...there fore be connected to a domestic hot water distribution net work according to its performance and power In case of leakages of water close the water supply and promptly notify the qualified perso...

Страница 5: ...gets out to the final user The special burner cools the flame and check the airflow necessary for the combustion set up cooled flames avoiding the loss of ther mal efficiency generating an optimal com...

Страница 6: ...tallation size Measurements in mm AC Hot water G Gas AF Cold water 52 52 100 100 8 5 7 0 92 5 100 100 92 5 7 0 8 5 11i 14i 304 1 7 6 1 9 6 2 8 6 4 1 6 5 8 AC G AF G H2 O 70 4 85 222 238 6 1 7 AC G AF...

Страница 7: ...able mechanism that com plieswith the applicable regulations Wall mounting Precautions Do not install this appliance in a room with an ambient atmosphere containing fatty and or corrosive dust or va p...

Страница 8: ...nce with the regulations in force Before installing the appliance blow into the gas pipe in order to remove any residue Connect the water heater to the gas pipe of the internal system and fit upstream...

Страница 9: ...uration combustion product exhaust is outside the home through concentric pipes while air intake is in the room where the appliance is installed TYPE C Horizontal coaxial exhausts In this configuratio...

Страница 10: ...l exhausts Lipari ProTfs 14i up to 1 45 from 1 to 1 9 47 from 1 9 to 3 7 not installed TYPE C Vertical coaxial exhausts Lipari ProTfs 11i up to 2 43 1 m 1 4 m from 2 to 3 7 45 from 3 7 to 6 7 not inst...

Страница 11: ...o 102 Pa Flangia fumo 46 mm 45 Pa Flangia fumo 44 mm 24 Pa Flange flues not installed Flange flues 45 mm Flange flues 43 mm Lipari ProTfs 11i 0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35 40 45 50 55 60...

Страница 12: ...entric or separate where combustion product exhaust is in one and combustion air intake in the other The outlets placed rather close to be subject to similar wind conditions C52 C52x Fume exhaust and...

Страница 13: ...water heater h h Open a hot water valve to full capacity Check the gas pressure referring to the values indicated in the data table If the pressure is higher than 15 mbar calibrate the gas valve Duri...

Страница 14: ...MTN 1 LPG h h If selected LPG gas the gas setted is propane If is necessary to set butane gas set parameter 13 to 2 h h To store the value press the reset button h h At the end of the procedure the a...

Страница 15: ...ter flow limiter l min 8 10 Continuous intake capacity T 35 K l min 8 10 Minimum ignition flow l min 2 2 Selectable water temperature C 37 60 37 60 Minimum pressure bar 0 13 0 13 Maximum pressure bar...

Страница 16: ...e necessary checks proceed with the following operations Electrically power the water heater Open the gas valve installed upstream of the water heater Open the water tap at the bottom of the water hea...

Страница 17: ...pear on the display release the button The appliance automatically restarts If the fault persists request the assistance of a qualified technician Permanent shutdown Domestic water NTC fault alarm IN...

Страница 18: ...consecutive times alarm Request the assistance of a qualified technician Temporary shutdown Button alarm This is displayed when you keep pressed the button for more than 30 seconds once the button is...

Страница 19: ...t fig 21 button for about 10 seconds the display symbols start to flash First the symbol is displayed and then the symbol h h Release the reset button h h Enter the code by turning the knob and confir...

Страница 20: ...oint 0 1 0 09 Ignition power 0 40 40 13 LPG gas type 1 propane 2 butane 1 2 1 17 Complete or partial calibration 0 100 0 18 Domestic hot water modulation with flow meter 0 modulation without flow mete...

Страница 21: ...button h h Press the reset button until MENU flashing release the button the display shows h h Press again the reset button until the display shows MENU flashing release the button the display shows t...

Страница 22: ...ectors Removing the gas valve Fig 28 Remove the casing by referring to the specific paragraph Unscrew the screws that secure the panel to the bottom shelf Remove the panel without disconnecting the wi...

Страница 23: ...cts whether it be new or old l Force majeure due to particular weather events e g earthquakes floods lightning storms excessive precipitation etc as well as fires vandalism theft stray currents and or...

Страница 24: ...Fax 39 0365 878 576 e mail info fondital it www fondital com The manufacturer reserves the right to modify his her products as deemed necessary without altering the basic characteristics of the produ...