- 31 -
Remark 1
:
The setting of auto shutdown time can be done by manufacturer or distributor. Setting range:
0~30 minutes. (In-plant setting: 5 minutes)
Remark 2
:
When the transmitter voltage is low, LV relay will be activated and siren or lights will be ON.
(One second of interval)
Remark 3
:
Every time when you change jumper settings you must first turn the receiver power off and then
turn it back on so that the new settings can be stored in the memory.
7.3.3 Alpha 612 Models Dip-Switch Function Table
※
※
In-plant all set as “0”
Model
Pushbutton
Dip-Switch Setting
Description
612AS
1 & 2
3 & 4
5 & 6
DIP 1
→
1
Not Interlocked
→
0
Interlocked
7 & 8
DIP 2
→
1
Not Interlocked
→
0
Interlocked
7 & 8
DIP 3
→
1
Latching/toggle relay contact
DIP2 must be set at “1”
→
0
Momentary relay contact
9 & 10
DIP 4
→
1
Not Interlocked
→
0
Interlocked
9
DIP 5
→
1
Latching/toggle relay contact
DIP4 must be set at “1”
→
0
Momentary relay contact
10
DIP 6
→
1
Latching/toggle relay contact
→
0
Momentary relay contact
612BS
7 & 8
DIP 1
→
1
Not Interlocked
→
0
Interlocked
7
DIP 2
→
1
Latching/toggle relay contact
→
0
Momentary relay contact
DIP4 must be set at “1”
8
DIP 3
→
1
Latching/toggle relay contact
DIP4 must be set at “1”
→
0
Momentary relay contact
9
DIP 4
→
1
Latching/toggle relay contact
→
0
Momentary relay contact
612C-1S/
612C-2S
1 & 2
(
2
nd
speed
)
DIP 1
→
1
Single contact relay activated
1
st
and 2
nd
speed contact
relays activated
separately
→
0
Two contact relays activated
When 2
nd
speed contact
relay is activated, 1
st
speed contact relay is
activated at the same
time.