6
8. Troubleshooting
PROBLEM
POSSIBLE CAUSE
REMEDY
Light-sensitive diode is not
functioning
Diode is turned off.
Check, whether or not the CELL
button is turned on.
The infrared light cannot reach
the IR sensor.
Change the position of the
infrared light, so it can reach
the sensor.
Too much ambient light is
interfering with the reception
sensor.
Move the equipment to a darker
environment.
Synchro cable is not working
The inside of the synchro
connector is dirty or dusty.
Clean the connector.
Shortcut in the synchro cable
or bad connection.
Change the cable (Press the
test button to check if the flash
is working properly).
The device is not working
Incorrect input voltage.
- Check the connection of the AC
input cord.
- Make sure all connectors are
hooked up properly.
- Check the fuse.
Other
Contact the nearest authorized dealer or retailer. Have the
equipment checked by an authorized dealer or retailer. This will
ensure correct function of the product and continuatien warranty
validity.
The manufacturer reserves the right to change the specification of the product, without previous notice
whatsoever.
9. Technical information
Model
Digitalis
Manufacturer
Fomei a.s.
Input voltage
AC 220-240V-50 Hz
Modelling lamp
Max. 100 W
Flash lamp fuse
250 V T5AL
Modelling lamp fuse
250 V T10AL
Safety distance from flash
Min. 1m