20. Turn power to icemaker OFF.
21. Disconnect transport tube from evaporator outlet
port. Rinse compression nozzle in clean water and
reinstall on evaporator outlet. Reconnect transport
tube to compression nozzle.
22. Drain any remaining sanitizing solution from
evaporator.
23. Fill reservoir almost to overflowing with clean,
120 F (49 C) water, and drain. Repeat three times.
24. Open water supply valve and replace reservoir
cover. Restore power to icemaker and ensure
compressor switch is in ON position. Make ice for
at least 15 minutes to flush any remaining solution
from system. Discard this and all ice made during
sanitizing.
25. Inspect evaporator drain pan and drain line and
remove any accumulated scale build up.
26. Replace any panels removed prior to cleaning.
Start-up following cleaning
1. Clean and sanitize ice storage area of dispenser in
accordance with instructions before making ice.
2. Turn icemaker on and begin to make ice. Icemaker
should start immediately with power and bin signal
supplied.
3. After approximately 30 minutes, test dispenser for
proper dispensing.