REF4/5 and REF5BB Compressor Retrofit
14. Connect wiring to new
compressor, be sure to
connect ground wire to the
body of compressor.
Fig. 10
15. Using a nitrogen purge, braze
all joints.
16. Leak check and evaccuate to
at least 500 microns for 30
minutes.
17. Charge unit with R404A
refrigerant (7.9 oz on REF 4/5
and 10 oz on REF 5BB)
18. The replacement compressor
is taller and will not allow the
drain pan to be installed in the
original position (on REF4/5
models).
§
Adhere the supplied Velcro tape
to the bottom of the drain pan
(Fig. 11).
Fig. 11
19. Reinsulate suction line with
supplied insulation and wire
tie in place using supplied wire
ties.