HC_1810R/N, HC_2110R/N, HM_1810R/N, HM_2110R/N 23
Fig. 17
10.
Remove 3 screws (with 3/16" allen wrench) then
remove auger and main housing together.
Note: Auger is sharp - wear protective gloves.:
Fig. 18
11.
Rotate auger to align opening in auger flange with
stream divider.
12.
Pull out auger.:
Fig. 19
13.
Remove and discard the ceramic mating ring and
shaft seal.