2
Horizon Elite 1010/1410 Ice Machines (Remote Condensing)
CAUTION
• Warranty does not cover exterior or outside installations.
• Moving parts. Do not operate with front cover removed.
• Hot parts. Do not operate with cover removed.
• To reduce risk of shock, disconnect power before servicing.
• Drain line must not be vented.
• Water supply must have particle filtration.
• Most ice machine cleaners contain citric or phosphoric acid, which can cause skin irritation. Read caution label
on product and follow instructions carefully.
• Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.
• Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.
Specifications
Electrical
Separate circuit and equipment ground required.
Evaporator unit
Standard electrical: 115/60/1
Maximum fuse: 15A
Amperage: 5A
Condensing unit
1010
Single-Phase
(Tecumseh)
1010
3-Phase
(Tecumseh)
1410
Single-Phase
(Tecumseh)
1410
3-Phase
(Tecumseh)
1410
3-Phase
(Larkin
LZT015M6CFIM)
1410
3-Phase
(Larkin
LCH0015MCACZ)
Electrical
208-230 V,
60 Hz
208-230 V,
60 Hz
208-230 V,
60 Hz
208-230 V,
60 Hz
208-230 V,
60 Hz
208-230 V,
60 Hz
Max Circuit
HVACR breaker
size
15A
15A
30A
25A
15A
20A
Min Circuit
Ampacity
10.7A
9.9A
19.3A
14.2A
15A
15A
Evaporator plumbing
§
3/8" OD push-in water inlet (connection inside machine) - 3/8" OD tubing required.
§
Water shut-off recommended within 10 feet (3 m).
§
Follett recommends installation of Follett water filter system (part# 00130286) in ice machine inlet water line.