Controller Security

The controller can be locked so that the set-points in the controller cannot be changed.

1.  To lock, press UP and DOWN arrows simultaneously until LOC appears (approximately 5 s).
2.  To unlock the controller, press up and down arrows simultaneously until UNL appears. Changes are 

only accepted when the controller is unlocked.

Changing Temperature Display from C to F

1.  Press SET and UP arrow simultaneously until L1 (first level menu) is displayed.
2.  Press the UP arrow until UNT is displayed. Press SET then use the UP and DOWN arrows to change 

the temperature display from F to C. Press 

SET to accept. The display will return to the temperature in 

approximately 10 s. 

Changing Temperature Display from Decimal to Integer

1.  Press SET and UP arrow simultaneously until L1 (first level menu) is displayed. Release.
1.  Press SET and UP arrow simultaneously until L2 (second level menu) is displayed.
2.  Press the UP arrow until rES is displayed. Press SET then use the UP and DOWN arrows to select Int 

(integer) instead of 

Dec (decimal). Press SET to accept.

Sleep Function

Press the 

SLEEP button to blank the display, or press any button to wake the display. If the unit goes into an 

alarm, the display will wake to display the alarm.

Minimum and Maximum Temperature Function

Records the highest and lowest temperatures logged by the probe selected to be displayed. Default display 
probe is P3 (product simulation bottle probe).

High and low log display

1.  Press the UP arrow to display the highest temperature the freezer has recorded since last reset or 

power cycle.

2.  Press the DOWN arrow to display the lowest temperature that the freezer has recorded since last reset 

or power cycle.

Reset high and low log

1.  Press UP or DOWN arrow until recorded temperature is displayed.
2.  Press and hold SET until RST is displayed.

Alarming Functions

Set high and low alarms

1.  Press and hold SET and UP arrows simultaneously until L1 is displayed. Use the UP and DOWN arrows 

to navigate parameters.

2.  The low temperature alarm parameter is AlL. Once the parameter is displayed, press SET to display 

the low alarm temperature. The alarm temperature will flash on the display. Use the 

UP and DOWN 

arrows to set the alarm temperature. Press 

SET to accept.

3.  The high temperature alarm parameter is AlH. Once the parameter is displayed, press SET to display 

the high alarm temperature. The alarm temperature will flash on the display. Use the 

UP and DOWN 

arrows to set the alarm temperature. Press 

SET to accept.

14 

FZR1/FZR2 Compact Freezers

Содержание fzr1

Страница 1: ...Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com Following installation please forward this manual to the appropriate operations person Installation Operation and Service M...

Страница 2: ...ing Temperature Display from Decimal to Integer 14 Sleep Function 14 Minimum and Maximum Temperature Function 14 Alarming Functions 14 Follett Keypad Lock KP models only 17 Service 18 Door Gasket Repl...

Страница 3: ...the type of freezer you are receiving Specifications Dimensions FZR1 FZR2 Dimensions external 18 6 W x 24 D x 17 93 H 47 cm x 61 cm x 46 cm 18 6 W x 24 D x 27 93 H 47 cm x 61 cm x 71 cm Dimensions int...

Страница 4: ...minimum air clearance required right or left side 6 15 3 cm minimum air clearance required right or left side SHELF 80 F 27 C and 60 RH unrestricted top clearance location Requires 2 5 1 cm clearance...

Страница 5: ...e the bottle from the bracket located in the upper right corner of the freezer Fig 2 2 Remove the top and fill the bottle with a 60 40 solution of glycerine and water 3 Replace the top and probe 4 Rei...

Страница 6: ...attery pack and the battery connector away from the hook and loop patch on the front panel Fig 4 3 8 Connect the battery connector with the black and red wires to the top of the battery pack 9 Place t...

Страница 7: ...torque on the spring Fig 6 4 With a flat head screwdriver simultaneously push down and pry the top of the spring from out of the top of the hinge Fig 7 Fig 7 5 Support door and remove screws attachin...

Страница 8: ...stall lock strike bracket to top inside of door Fig 9 2 10 Reverse door 180 so that lock strike bracket is on the bottom inside of door Fig 9 3 Fig 9 1 2 3 11 Reinstall the door on the opposite side o...

Страница 9: ...ing kit onto top hinge pin Fig 12 2 Fig 12 1 2 1 Adjusting Hinge Closure Force 1 Remove the tool and insert it Phillips screwdriver Allen key drift pin into hole nearest the hinge bracket Fig 13 Fig 1...

Страница 10: ...l hinge cover Fig 16 Fig 16 Installing Third party Temperature Probe Facilities using a third party alarming and or temperature monitoring system need to install the third party probe in the freezer F...

Страница 11: ...end of wire to remove slack from inside of freezer 9 Use Permagum or equivalent sealant to replace foam insulation removed in Step 5 to ensure proper performance of freezer 10 Remove any debris that...

Страница 12: ...g 20 1 2 Operation The temperature control board and probe P1 indicate when the refrigeration system is required to turn on and off The refrigeration system removes heat from the cabinet interior and...

Страница 13: ...play In normal operation the controller displays simulation bottle temperatures in degrees celsius C or user selected degrees fahrenheit F Temperatures can be displayed to one decimal point The contro...

Страница 14: ...f the unit goes into an alarm the display will wake to display the alarm Minimum and Maximum Temperature Function Records the highest and lowest temperatures logged by the probe selected to be display...

Страница 15: ...codes Value Description HA1 Temperature is above the High Alarm 1 set point LA1 Temperature is below the low Alarm 1 set point HA2 Temperature is above the High Alarm 2 set point LA2 Temperature is be...

Страница 16: ...ously again until L2 is displayed 3 Use the UP and DOWN arrows to navigate the parameters When the desired parameter is displayed press SET 4 Use the UP and DOWN arrows to navigate the sub menu of the...

Страница 17: ...ps will be heard 3 Enter the new user code 4 to 6 numbers followed by ENTER 3 chirps will be heard 4 Re Enter the new User Code Followed by ENTER 5 chirps will be heard to acknowledge that a new code...

Страница 18: ...ing refrigerant lines 1 Remove rear panel Fig 23 2 Remove two screws facing downward that secure the panel assembly to the base plate 3 Loosen the six screws that secure the rear panel to the back of...

Страница 19: ...the front of the module Fig 26 5 Lift the module and pull forward Fig 26 Refrigeration System The refrigeration system is designed to give many years of trouble free service Except for routine cleanin...

Страница 20: ...UNIT EVAPORATOR DEFROST UNIT EVAPORATOR FAN Low Pressure Vapor High Pressure Vaport Low Pressure Liquid High Pressure Liquid 10oz Charge FAN COMPRESSOR LOW PRESSURE LIQUID HIGH PRESSURE LIQUID LOW PR...

Страница 21: ...EATER MAGNET DOOR SW t WHT ON OFF 01 BLK L1 115 VAC 1 60 RELAY COMPRESSOR 1 2 4 3 03 BLK 08 ORG 06 RED 05 BLK RELAY HEATER DEFROST PAN P1 P2 P3 P6 P7 BOTTLE PROBE DEFROST PROBE CONTROL PROBE ALARM 1 C...

Страница 22: ...fective Replace as required Compressor defective Replace compressor Evaporator fan motor does not run Defective fan motor Replace fan motor Freezer does not shut off Controller not sensing cut off tem...

Страница 23: ...Digital data logger includes the following Description Part Temperature probe certificate of traceability Calibration by Dickson NIST and ISO IEC 17025 01057595 DicksonWare software and USB cable 0105...

Страница 24: ...24 FZR1 FZR2 Compact Freezers Replacement Parts 12 13 7 8 16 5 6 10 9 4 14 1 2 3 15 11...

Страница 25: ...racket and hardware 01081702 7 Lock deadbolt with keys 00959528 8 Bracket lock mounting 01095843 9 Panel front 01081660 Not shown Panel front with keypad 01081678 10 Battery pack includes harness 0108...

Страница 26: ...01085000 3 Fan guard evaporator 00940452 4 Fan evaporator 00940460 5 Evaporator 01017961 6 Thermal expansion valve 01081785 7 Drain pan assembly evaporator FZR1 2 01086917 8 Defrost heater FZR1 2 0106...

Страница 27: ...ket 00958694 6 Start relay compressor 01074723 7 Start capacitor compressor 01062348 8 Coil condenser 01041565 9 Motor fan condenser 00940460 10 Drier filter 01068857 11 Fan shroud condenser FZR1 0104...

Страница 28: ...Not shown Control board keypad FZR1 2 KP models 01081801 2 Compressor defrost relay 01042092 Not shown Probe temperature 01062801 3 Mounting plate control board 01097955 Not shown Stand offs control b...

Страница 29: ...FZR1 FZR2 Compact Freezers 29...

Страница 30: ...30 FZR1 FZR2 Compact Freezers...

Страница 31: ...FZR1 FZR2 Compact Freezers 31...

Страница 32: ...egistro de la garant a y evaluaci n del equipo son importantes para que podamos realizar un seguimiento de nuestro equipo y registrar el rendimiento de la maquinaria Por favor registre las garant as d...

Отзывы: