Fogo Montanha Versatile H600 Скачать руководство пользователя страница 2

2

FOGO MONTANHA, t

he manufacturer of  free standing fire units  hereby represents  that they are the sole responsible for

the  compliance  of  all  models  described  hereunder  with  the  general  safety  requirements.  Any  changes  made  to  the
product without the previous written consent from the manufacturer will void the above statement.

1. INTRODUCTION

Thank you for choosing a

 FOGO MONTANHA

free standing fire unit. In order to get the best performance from your unit,

while complying with the applicable eco-standards, carefully follow the installation and operation instructions provided in
this  manual.

Any  damage  to  the  unit  due  to  non-compliance  with  the  instructions  shall  void  the  warranty

.  Any

changes  to  the  free  standing  fire  unit  are  subject  to  the  previous  written  consent  from  the  manufacturer.  Only  original
replacement parts  may be  used  with this unit. Following are the  applicable national  legislation,  local  building codes and
standards, and fire prevention regulations.

2. TECHNICAL SPECIFICATIONS:

3. WOOD

This free  standing fire unit  operates exclusively on  wood.  We recommend that  you use seasoned  wood that has been
chopped, stored, and conditioned in a covered area for at least one, but preferably two year(s) because:

  It produces substantially more heat than damp or green wood.

  It produces considerably less smoke and leaves less tar deposit in the unit, chimney, and glass panel, than damp or

green wood.

  It is the only unit that prevents the emission of harmful substances during burning.

  Damp wood can damage and corrode the unit, originating rust within a short period of time.

You should use wood logs of medium size. Rule of thumb: the heavier the wood the better the performance. Never burn
wood shreds, chips or sawdust, cork, laminated or treated wood. Do not burn small size wood logs as they burn too fast.
Use them  only for lighting  the fire. Allow  wide  wood  logs, of  approximately 25 cm (9.8 in), to burn naturally. Wider logs
should be chopped.
Note: Your free standing fire unit is not a waste incinerator. The environmental legislation expressly prohibits the use of
domestic  units  for  burning  waste.  Additionally  to  being  harmful to the environment, the use a solid-fuel heating unit

   Versatile S600

   Versatile S600 SE

Versatile H600

%

75.00

75.00

78.00

Kg/Hour

2,7

2,7

2,4

m3

235.00

235.00

268.00

kW

7.90

7.90

9.10

Vol.%

0,09

0,09

0,1

Vol.%

10,2

10,2

9,7

mm

150.00

150.00

180.00

kW

8,5

8,5

9,1

cm

100.00

100.00

100.00

Kg

114.00

114.00

131.00

wood

wood

wood

%

20.00

20.00

20.00

cm

40.00

40.00

40.00

mm

523.00

523.00

665,5

mm

576.00

576.00

576.00

mm

429,5

429,5

429,5

Manufacturer 

Fogo Montanha (Solzaima, S.A.)
Rua dos Outarelos, 111
3750-362  Belazaima do Chão, Portugal
Tel: +351 234650650  Fax: +351 234650651

Classification 

Solid-fuel heating appliance

Standards 

and 

regulations

compliance

EN13229: 2001+ A1:2003 + A2:2003:2005

Entity responsible for testing 

Laboratório Recupera
Algarve University
Campus da Penha
8005-139 Faro

Laboratory K.V.B.G. – A.R.G.B
Rodestraat 125
1630 Linkebeek, Belgium

Содержание Versatile H600

Страница 1: ...Starting combustion 5 10 Controls 5 11 Lighting the free standing fire 5 12 Managing the free standing fire 6 13 Cleaning 6 14 Maintenance 7 15 Troubleshooting 10 16 Warranty 10 HIGH TEMPERATURE HEATI...

Страница 2: ...amp or green wood It is the only unit that prevents the emission of harmful substances during burning Damp wood can damage and corrode the unit originating rust within a short period of time You shoul...

Страница 3: ...imney has been out of operation for a long time you should have it checked by an expert The chimney must have enough height to allow for fume exhaustion at 12 20 Pascal minimum The fume exhaustion can...

Страница 4: ...cialists Please keep in mind the following considerations The door of the appliance must be closed at all times irrespective of the appliance s operating status on off The household must allow for a p...

Страница 5: ...ich upon condensation causes the build up of tar onto the combustion chamber chimney and glass panel A tar build up not only is unpleasant to the eye but it also requires regular chimney cleaning to p...

Страница 6: ...nd convection heat output Very high wood consumption Fully open the aeration control to create a fast burning flame This setting should only be used to light the unit Once the appliance is hot you sho...

Страница 7: ...information on the requirements of the Clean Air Act can be found here http smokecontrol defra gov uk Your local authority is responsible for implementing the Clean Air Act 1993 including designation...

Страница 8: ...oxidation The same caution applies to the sealing rope and other components which may be damaged if in contact with these products 4 Allow the cleaner to work 5 Wipe off tar deposits using a slightly...

Страница 9: ...a year To do this remove the smoke damper Fig 1 from the unit To remove the smoke damper follow the steps below 1 Open the door to remove the smoke deflector Fig 2 To do this place a hand on the smok...

Страница 10: ...lly hold the replacement glass leaning the upper end against the top part of the door the bottom end will slide into place 3 Slide the glass downwards towards the bottom of the door to fit the upper e...

Страница 11: ...hen place the glass on the top of the metal brackets and level with the base Table This base can be mounted in three different positions Position A Left hand side Position B Central Position C Right h...

Страница 12: ...ype of fuel used and the handling of the unit are beyond FOGO MONTANHA s control so parts in direct contact with the flame are not covered by this warranty for instance glass sealing bundles and vermi...

Страница 13: ...S600 UK V1 2014...

Отзывы: