7
transmitter within 15 seconds after power is turn on. When new transmitter is registered previous
transmitter will be automatically deleted.
Transmitter battery replacement
If the effective distance seems to decrease, it is possible the battery level is low and requires replacement.
In order to replace the battery, undo the three screws on the back of transmitter to release the cover.
Replace with the same type and specification of battery which is 27A 12V
Fluid
Only use Fog Defense FLE Antibacterial solution for FD-800. The
machine is tested and calibrated with this liquid to get the best
output performance. Warranty will be voided if any other type of
liquid is used, improper use of liquid may lead to machine failure
and malfunction.
Service and Maintenance
․
Do not allow the machine to become contaminated.
․
Remove dust from air vents with air compressor, vacuum or a soft brush.
․
Only use a damp cloth to clean the casing.
․
Before storing run distilled water through the system to help prevent condensing the pump or heater.
․
It is recommended to run the machine on a monthly basis in order to achieve best
performance and output condition.
․
Excessive dust, liquid and dirt built up will degrade performance and cause overheating.
Fuse Replacement
Disconnect AC power before resetting the breaker. Only replace fuse with same type and
rating.
Step 1:
Disconnect AC power.
Step 2:
Use a flat-head screwdriver to release fuse holder.
Step 3:
Replace fuse with exact same type and rating as indicated below.
Step
4:
Reinsert fuse holder