ISA TWO CONTROLS AND FEATURES

Front Panel

Channel Controls

Input Selection

Each press of the 

Input

 button steps through the three available input sources: Mic/Line/Instrument.

Phase

Pressing 

Phase

 inverts the polarity of the selected input. This can be useful when multiple mics are 

used in close proximity (ie., on a drum kit).

Mic Input Gain

The 

Gain

 switch adjusts the mic gain in three 10 dB steps. Its range is either 0–30 dB or 30–60 dB 

when the 30–60 switch is pressed. An additional 0–20 dB of continuous gain adjustment is available 
using the 

Trim

 control.

To avoid an excessive jump in level, It is recommended that the stepped Gain switch is turned to minimum before 
pressing the 30-60 switch.

Before starting a recording, or if used for PA/live work, set the Trim control to near its centre position. This will allow 
for some gradual gain adjustment up or down without the use of the stepped control.

Channel 1

Channel 2

Power 

switch

Instrument 

inputs

LED 

meters

Applies 

+48V

 

phantom power to 

the mic input XLR

Inverts polarity 

(

Phase

) of the 

selected input

Input 

Trim

 pot         

Mic/Line: 0 +20 dB 

Instrument: +10 +40 dB

Applies the 

variable-frequency 

high-pass 

Filter

 to 

the selected input

Filter roll-off 

frequency 

pot

Mic and 

Instrument input 

impedance (

Z In

selection

Switches the external 

Insert

 return into the 

channel path

Input

 

source 

selection

Selects the high 

(

30-60

 dB) mic 

gain range on the 

Gain switch

10 dB stepped Mic/

Line 

Gain

 switch 

Mic: 0-30 / 30-60  

Line: -20 +10

Содержание ISA TWO

Страница 1: ...User Guide focusrite com FA0540 03 Two channel classic transformer mic pre...

Страница 2: ...ut Impedance 5 Filter 5 Insert 5 Meter Calibration 6 Rear Panel 7 AC Mains Inlet 7 Channel Mic Inputs 7 Channel Line Inputs 7 Channel Outputs 7 Channel Insert Sends Returns 7 Meter Calibration Pot 7 P...

Страница 3: ...e ISA Two The ISA Two provides two of Focusrite s prestigious transformer based microphone preamps and can be used to record microphone line level or instrument sources Microphones and line level sour...

Страница 4: ...Gain switch is turned to minimum before pressing the 30 60 switch Before starting a recording or if used for PA live work set theTrim control to near its centre position This will allow for some grad...

Страница 5: ...impedance options The values are shown in the table For additional information on impedance selection see Appendix 2 Preamp Input Impedance on page 10 With the Instrument input selected pressing the s...

Страница 6: ...lt calibration is for 0 to indicate a signal level of 22 dBu Meter Calibration The level at which the 0 LED illuminates can be adjusted using the Peak Meter Calibration pot on the rear panel The defau...

Страница 7: ...4 TRS jack sockets Channel Outputs On XLR 3 male connectors Channel Insert Sends Returns Analogue sends and returns on balanced 1 4 TRS jack connectors The insert signal is added into a channel path...

Страница 8: ...ounted in a rack these vents are not obstructed Do not mount the unit immediately above any other equipment which generates significant heat for example a power amplifier Note The maximum operating en...

Страница 9: ...creen 2 Hot ve 3 Cold ve Pin Signal 1 Screen 2 Hot ve 3 Cold ve Instrument Input Connector Unbalanced TS 1 4 Jack socket Line Input Insert Send Insert Return Connector Balanced TRS 1 4 Jack socket Pin...

Страница 10: ...Impedance In Depth Explanation Dynamic Moving Coil and Condenser Microphones Almost all professional dynamic and condenser microphones are designed to have a relatively low nominal output impedance of...

Страница 11: ...es an output transformer to convert the low voltage it generates into a signal capable of being amplified by a preamp The transformer uses a ratio of around 1 30 primary secondary to increase the ribb...

Страница 12: ...12 Appendices 3 Pro Tools Interfacing Analogue out to Pro Tools HD ISATwo Red 16Line 2 x XLR 3 female DB25 male analogue Pro Tools interface...

Страница 13: ...n Z In Low unless otherwise stated RS 50 Measurements taken at the analogue outputs Gain Range 20 to 10 dB in 10 dB steps plus 0 to 20 dB continuous trim Maximum Input Level 25 dBu Input Impedance Ele...

Страница 14: ...imensions Height 88mm 3 46 Width 482mm 18 98 Depth 325mm 12 8 Weight Weight 3 70 kg 8 12 lbs Output Level Maximum output level 24 dBu Environmental Operating Temperature 40 C 104 F Maximum ambient ope...

Страница 15: ...of the appropriate procedure for resolving the warranty issue In every case it will be necessary to provide a copy of the original invoice or store receipt to the distributor In the event that you ar...

Отзывы: