Operating instructions

 BUILDING, STARTING AND MAINTAINING THE FIRE

 CAUTION

DO NOT LIGHT A FIRE WITH ASH REMOVAL HATCH REMOVED, AS THIS WILL PRODUCE OVER-FIRING OR 

HOUSE FIRE. DAMAGE CAUSED FROM NON-OBSERVANCE OF THIS CAUTION IS NOT COVERED UNDER 

FOCUS LIMITED WARRANTY.

Do not overload your focus fireplace to avoid over-firing.

Build the fire without elevating it, directly on the grate. not too close to the glasses. For starting the fire, we recommend using 

a small amount of fire starter with enough kindling (small logs or mill ends) to establish a primary fire.

Fresh air intake must be fully open (pull the handle towards you) as for damper (handle vertical).

After a few minutes, and making sure the primary fire is well started, add larger wood (between 3 and 7 pieces, depending on 

their size), directly on top, making sure not to smother the fire. Leave some spaces between the logs for air intake.

To maintain or refuel your fire, add when needed (see note), a few larger logs.

NOTE :

 For the same weight of fuel, 10 logs will burn more intensely (and faster) than 3 logs, but you will get the same heat 

power at the end. The log size you buy will determine the heating and refueling time.

 PROTECTIVE GLOVE

The use of the focus special protective glove supplied with our models is required upon handling the damper, fresh air controls, fire 

irons controls, fire irons, etc.

 DAMPER OPERATION AND USE

Use of supplied cold handle tool or protective glove is recommended to operate the damper. Do not touch the damper handle without 

protection when a fire is operating.

The Emifocus damper has four positions. The damper is in the same direction as the handle: when the handle is vertical, the damper 

is fully open. Handle can rotate at 30°, 60° and 90° (horizontal : closed). In closed position the damper obturates by 75% the flue 

section. To modify the damper position, first pull the handle, then rotate and push again

the handle in order to lock on a preset position.

 CAUTION

NEVER ADJUST THE DAMPER HANDLE ON AN INTERMEDIATE POSITION !

The damper position must be adapted to the fire intensity : during the lighting it must be fully open. Then it must be adjusted in order 

to reduce the smoke flow, so the heat efficiency will be optimal. If the smoke spills out it means the damper is too obstructive : re-

open the damper at the first signs of spillage.

Содержание Emifocus

Страница 1: ...tories Inc and approved to UL 737 2011 and ULC S627 00 US EPA exempt Report Number 0304WF008S This document was packed with the appliance KEEP THESE INSTRUCTIONS FOR FUTURE USE EMIFOCUS ____ DESIGN INSTALLATION OPERATING MANUAL ...

Страница 2: ...iance designation émifocus d v Manufacturer Focus Atelier Dominique Imbert Le fort 34380 Viols le fort France Introduction Specifications CHARACTERISTICS ROOF OUTLET REQUIREMENT CHIMNEY REQUIREMENT STRUCTURAL REQUIREMENT CONNECTOR FRESH AIR INTAKE CLEARANCES TO COMBUSTIBLES A CLEARANCES TO FLOOR AND CEILING B CLEARANCES TO SIDE WALLS Installation INCLUDED PARTS MATERIALS AND REQUIRED TOOLS FOR INS...

Страница 3: ...y result To reduce the risk of fire follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in your area CHARACTERISTICS Hearth weight 115 lbs 52 kg Flue diameter 8 5 8 inch 219mm length custom made Flue weight 11 lbs per foot 16 kg per meter Wall anchor plate weight approx 22 lbs 10 kg 1 8 inch 3 2 5 mm thick steel ...

Страница 4: ...feet minimum 13 feet for an installation less than 3 miles from the ocean or if a 30 elbow is necessary The émifocus must be connected to a chimney complying with the requirements for Type HT chimneys in the standard for Chimneys Factorybuilt Residential Type and Building Heating Appliance UL 103 For example a class A insulated stainless steel flue chimney system with an 8 inch minimum inside diam...

Страница 5: ...or roof space closet or similar concealed space or a floor or ceiling Passage through an attic roof frame floor or ceiling must be done using an insulated chimney respecting all chimney manufacturer clearances CAUTION PASSAGE THROUGH A WALL OR PARTITION OF COMBUSTIBLE CONSTRUCTION IS NOT AN APPROPRIATE INSTALLATION FOR THIS FOCUS FIREPLACE FRESH AIR INTAKE For optimum functioning focus requires a ...

Страница 6: ... floor heating tubing under the fireplace pas de chauffage au sol non combustible surface R 1 2 surface non combustible R 1 2 combustible sub floor sol combustible 20 50 cm 8 200 mm 8 200 mm 16 40 cm US 18 45 cm Canada wall mur wall mur non combustible surface R 1 2 surface non combustible R 1 2 Specifications ...

Страница 7: ... CAN OCCUR IF THIS DISTANCE IS NOT MAINTAINED DRYWALL PRODUCTS LINED WITH PAPER SUCH AS SHEETROCK ARE COMBUSTIBLE CLEARANCES AS INDICATED FURTHER APPLY Manufacturer specifications Corner configuration this configuration necessit that you build an additional wall in the corner of the room When placed close to a noncombustible wall leave a minimum of 4 inches from hearth which has a 27 9 16 diameter...

Страница 8: ...rill M8 allen key level screwdrivers M12 key scaffolding refractory compound 2 persons minimum are required for installation OPTIONS Custom ceiling cover disc steel disc cover disc screw kit Focus steel flue extension ASSEMBLY DETAILS A SIDE CUT PLATE DETAIL metal studs frame structure métalliques 1 rock wool 25 mm laine de roche coupe de côté du émifocus ambient air air ambiant 1 2 12 mm cement b...

Страница 9: ...9 Installation B WALL MOUNTING INSTALLATION 24 13 16 630 mm 7 7 8 200 mm 6 diameter Ø150 mm b fresh air intake arrivé d air frais ...

Страница 10: ...0 Installation C FLUE PIPE INSTALLATION 6 7 32 X 6 1 2 160 mm X 165 mm 6 diameter Ø150 mm damper clé de tirage fresh air intake adjustement ajustement de l arrivé d air frais 7 7 8 200 mm 24 13 16 630 mm ...

Страница 11: ... finition slip connector same brand as the chimney réduction conique même marque que le conduit de cheminée focus 8 universal adaptor adaptateur universel focus 200 mm cover disc with collar disque cache avec collerette focus steel flue conduit focus Ø14 mini Ø355 mm mini this point 3 mini below finished ceiling ce point est à 75 mm mini dessous le plafond fini ...

Страница 12: ...ed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled FUEL CAUTION DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGIN...

Страница 13: ...ess The first fire should be a modest one do not use packing material or pallet wood for fuel The paint finish we use oven baked at 250 C for 30 minutes is thermo plastic Because of the very gradual polymerisation of the components the unit may give off a light smoke the first few times the fire is lit The painted surfaces nearest the fire may while hot acquire a certain viscosity or slight sticki...

Страница 14: ...gs but you will get the same heat power at the end The log size you buy will determine the heating and refueling time PROTECTIVE GLOVE The use of the focus special protective glove supplied with our models is required upon handling the damper fresh air controls fire irons controls fire irons etc DAMPER OPERATION AND USE Use of supplied cold handle tool or protective glove is recommended to operate...

Страница 15: ...ue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney and chimney connector should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred If a significant layer of creosote has accumulated 3mm or more it should be removed to reduce the ri...

Страница 16: ...03 Middleton MA 01949 T 781 324 8383 www europeanhome com DO NOT SCRUB CAUTION Cast iron grate Cold handle Touch up paint All of our focus models are guaranteed against any defect in design construction or manufacture and guaranteed to function properly for 5 years from date of order Our product guarantees are applicable only when our fireplaces have been installed with respect to all local buildi...

Страница 17: ...e R value of the proposed alternate floor protector I Use the formula in step 1 to convert values not expressed as R II For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the system is greater than the R value of the specified floor protector the alternate is acceptable EXAMPLE The specified floor protector should be 3 4 inch thick material with...

Страница 18: ...18 Note ...

Страница 19: ...19 Note ...

Страница 20: ...V 3 Janvier 2020 cheminées contemporaines ...

Отзывы: