Focus ATOM 3000 Скачать руководство пользователя страница 10

   

 

9B 

 

 

 

 

CONTROL ADDRESS 

The control address, also known as the start channel, is the first channel used 

to receive instructions from the controller. The address may be any channel 

from 1 to 511 and is set on the Address DIP switch. 

 

The BF-3000D uses 1, 3, or 4 channels depending on the control mode. For 

independent control, each fixture must be assigned its own address and non - 

overlapping control channels. Two or more BF -3000Ds may share the same 

address if individual control is not required. 

DMX 512 Address Chart: 

Dip-switches 

# 1 

# 2 

# 3 

# 4 

# 5 

# 6 

# 7 

# 8 

# 9 

#10 

Value 

16 

32 

64 

128 

256 

No effect 

 

     

 

 Examples: 

Unit 1

dip / on: #1 (=1) 

Unit 2

dip / on: #1, #2, #3 (1+2+4=7) 

Unit 3

dip / on: #1, #3, #4 (1+4+8=13) 

Unit 4

dip / on: #1, #2, #5 (1+2+16=19) 

 

Содержание ATOM 3000

Страница 1: ...ATOM 3000 BF 3000D User Manual Please read the user manual before use...

Страница 2: ...Contents Safety Information 3 Rear Panel 4 Preparation for Use 5 How to replace the Lamp and fuse 6 Controller Operation 8 Stand alone Operation 12 Remote Control 12 Test Function 14 Technical Specif...

Страница 3: ...ies with local building and electrical codes and has both overload and ground fault protection Do not expose the fixture to rain or moisture Replace the lamp only as described or have it replaced by c...

Страница 4: ...against falls When suspending the fixture above ground level verify that the structure can hold at least 10 times the weight of all installed devices Verify that all external covers and rigging hardwa...

Страница 5: ...set function mode 3 Preparation for Use UNPAKING The BF 3000D comes with the following items PX 3000 xenon lamp installed Mounting bracket User manual The packing material protects the fixture during...

Страница 6: ...ng bracket stud 3 Make clear the direction of left and right side of bracket and lock the screws After that tighten one hand knob to lock the mounting bracket in one end of bracket 4 Replace the Lamp...

Страница 7: ...re replacement 1 Disconnect the fixture from AC power and allow the capacitor to discharge for 1 minute 2 When the fixture is cool remove the two marked screws on the sides of the fixture and open the...

Страница 8: ...are wired in parallel both inputs connect to both outputs For reliable data transmission use one input and one output To connect the data link 1 Connect the DMX data input from the controller to the...

Страница 9: ...fast Continuous Blinder effect 3 channel DMX mode provides control of flash intensity flash duration and flash rate for more advanced control than 1 channel mode To select 3 channel DMX operation set...

Страница 10: ...4 channels depending on the control mode For independent control each fixture must be assigned its own address and non overlapping control channels Two or more BF 3000Ds may share the same address if...

Страница 11: ...flashes per second to 17 5 flashes per second Hz on 50 Hz power supplies or from 0 to 20 flashes per second on 60 Hz power supplies on channel 3 in the 3 and 4 channel DMX modes Flash rate is also co...

Страница 12: ...1 Lamp power is electronically regulated to prevent the lamp from overheating The intensity falls as power is reduced Single Flash To trigger single flashes start with the intensity and flash rate at...

Страница 13: ...roller BF 04D This section describes how to operate The BF 3000D with optional remote controls How to connect Connect to the remote control BF 04D and select the BF 04D mode in BF 3000D remote control...

Страница 14: ...ity is controlled from 20 of the maximum Intensity to 100 of the maximum Intensity with the DIMMER fader The maximum intensity is reduced in low power mode which is selected on pin 6 of the Mode DIP s...

Страница 15: ...N No matter if BF 3000D has DMX512 signal input from controller it will automatically test the light intensity speed and blind effect of the lamp 9 Technical Specifications Approved AC power 200 240 V...

Страница 16: ...15B Innovation Quality Performance...

Отзывы: