background image

INSTALLATION A

AND U

USER

INSTRUCTIONS

All iinstructions m

must bbe hhanded tto uuser ffor ssafekeeping

Revision A - 05/04

Country(s) of destination - GB/IE

MULTIFLUE G

GAS FFIRE

RANGE

BLENHEIM SSTYLE

ELEGANCE

LULWORTH

Focal Point Fires plc, Christchurch, Dorset BH23 2BT

Tel: 01202 499330     Fax: 01202 499326

www.focalpoint.co.uk

e-mail: [email protected]

Содержание MULTIFLUE GAS FIRE RANGE

Страница 1: ...o u user f for s safekeeping Revision A 05 04 Country s of destination GB IE MULTIFLUE G GAS F FIRE RANGE BLENHEIM S STYLE ELEGANCE LULWORTH Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 0120...

Страница 2: ...t person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instructions before com...

Страница 3: ...i installation a and u use o of t this a applianc ce This a applianc ce i is f free f from a any y a asbestos m material R Refrac ctories a and c coal b bed a are c construc cted from c ceramic c f f...

Страница 4: ...flue must not vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the appliance is installed into and the one venting the ga...

Страница 5: ...ack of the appliance must have a 50mm mini mum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flu...

Страница 6: ...3 ICP3 IS 327 and any other rules in force PREFABRICATED F FLUE B BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram b...

Страница 7: ...upplied A small incision can now be made in the rubber to slip snugly around the outside of the supply pipe and sleeving Note D DO NOT install or use the appliance without this seal in place If the ho...

Страница 8: ...lace openings Any sleeving should be sealed to the pipe at its ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABLE FIXIN...

Страница 9: ...e and firefront will clear the supply route If the data control plate is not already fitted attach with two screws ensuring the control knob is free to be depressed fully FUEL BED LAYOUT Fit the taper...

Страница 10: ...six pebbles on to the matrix Ensure the pebbles are firmly against the side cheeks as shown in the photograph If necessary pull the peb bles forward slightly to ensure their rear edges do not overhang...

Страница 11: ...k There should be no need to adjust this If under any circumstances the electric spark fails the pilot may be lit manually by proceeding with the ignition sequence as previously described and after tu...

Страница 12: ...Paint only when the fire is OFF and cold Always mask off the surrounding area to pre vent contamination with overspray Ventilate the room during the use of the spray DO NOT attempt to spray paint the...

Страница 13: ......

Страница 14: ...ow clear Release the screw through the supporting leg and lift assembly clear The injector pipe can now be checked for debris Remove the nut retaining the injector elbow Blow through the elbow to remo...

Страница 15: ...f for a a t time a and t then c cuts o off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pil...

Страница 16: ...the elderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See re...

Страница 17: ...the PILOT light position ensur ing the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten sec onds Now relea...

Страница 18: ...fire and flue should be checked on an annual basis to ensure all of the product of combustion are entering the flue and that there is no excessive build up of soot The frequency of service will depen...