Focal Point LEIRVIK EF09-19 Скачать руководство пользователя страница 3

3

©

2018 Focal Point Fires plc.

2.0 INSTALLATION REQUIREMENTS

3.0 APPLIANCE DATA

Supply Voltage and rating power : 220-240V AC 50Hz, 1500 - 1800W

Fuse Rating :

13 Amp

Heating Elements :

1500 - 1800W

Lighting :

LED Light Strip

Location :

Indoor use only

Supply plug/cord : BS1363/1.8 metres length

This product is only suitable for well insulated spaces or occasional use. The appliance is supplied with a pre-wired three pin BS1363

plug (13Amp fuse rated) and 1.8 metres of electrical flex. It is therefore necessary for a suitable electrical socket to be located within

this distance of the appliance and be easily accessible. The stove may be installed on a combustible or non-combustible floor, however

the heater outlet is underneath the stove and certain types of floor covering may be affected by the heat produced by the stove. The

ability of the floor covering to withstand the heat produced by the stove should be ascertained before proceeding with the installation

of the stove. If in doubt then the stove should be mounted on a non-combustible hearth or plinth which extends at least 150mm in front

of the stove.This appliance should be positioned on a firm level surface.  If the stove is to be sited in a fire surround then the suitabili-

ty of the surround for use with electrical heaters should be established with the fire surround manufacturer.If fitted into an open draught

fireplace, it is advisable to block off the chimney to reduce the risk of draught through the stove which may cause the safety cut out sys-

tem in the fan heater to operate.

• DO NOT run the mains cable under carpets, rugs etc.

• DO NOT cover or obstruct the heater in any way. Overheating will result if it is acci-

dentally covered.

• Never immerse the product in water or any other liquids.

• DO NOT use the appliance outdoors.

• Before cleaning the appliance, ensure it is unplugged from the power and that it is com-

pletely cool.

• DO NOT clean the appliance with abrasive chemicals.

• Never use accessories that are not recommended or supplied by the manufacturer. It

could cause danger to the user or damage to the appliance.

• DO NOT insert or allow foreign objects to enter the inlet or outlet vents as this may

result in electric shock, fire or damage to the appliance.

• DO NOT install the fire using an extension cord.

• Unplug from the mains supply if the appliance is not to be used for long periods.

1.0 IMPORTANT NOTES - CONTINUED

GB IE

Model

EF09-19

Item

Symbol

Value

Unit

Item

Unit

Heat output

Types of heat input, for electric storage local

space heaters only 

Nominal

heat output

Pnom

1.6

KW

Manual heat charge control with

integrated thermostat

N/A

Minimum heat

output

(indicative)

Pmin

N/A

KW

Manual heat charge control with

room and/or outdoor temperature

feedback

N/A

Maximum

continuous heat

output

Pmax, c

1.6

KW

Electronic heat charge control with

room and/or outdoor temperature

feedback

N/A

Auxiliary electricity consumption

Fan assisted heat output

N/A

At nominal

heat output

elmax

0.0

KW

Type of heat output/room temperature control

At minimum

heat output

elmin

0.0

KW

Single stage heat output and no

room temperature control

No

In standby mode

elSB

0.0

KW

Two or more manual stages no tem-

perature control

No

With mechanical thermostat room

temperature control

No

With electronic room temperature

control

No

Electronic room temperature con-

trol plus day timer

No

Electronic room temperature con-

trol plus week timer

Yes

Содержание LEIRVIK EF09-19

Страница 1: ...use Please note Except where otherwise stated all rights including copyright in the text images and layout of this booklet is owned by Focal Point Fires plc You are not permitted to copy or adapt any...

Страница 2: ...attention has to be given where children and vulnerable people are present If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in ord...

Страница 3: ...O NOT cover or obstruct the heater in any way Overheating will result if it is acci dentally covered Never immerse the product in water or any other liquids DO NOT use the appliance outdoors Before cl...

Страница 4: ...it two levelling feet behind the two front cast legs Unscrew in a anti clockwise orientation to extend the feet and clockwise to contract the front legs The fires levelness can be checked by using a s...

Страница 5: ...minutes the fire will Automatically alarm OP and turn off heating You can press Heater for 3 seconds or turn off the fire then turn it on to Eliminate the OP alarm When the fires is turned on and with...

Страница 6: ...mperature of each day from Sunday to Monday in mode 1 7 After setting press the OK button and the system will run the week timer of 1 7 models You can also set 1 7 modes within 1 day use auto mode to...

Страница 7: ...qualified electrician This appliance is supplied with a BS1363 3 pin plug fitted with a 13 Amp fuse Should the fuse require replacing it must be replaced with a fuse rated at 13 Amp and approved to B...

Страница 8: ...upply us with your proof of purchase 2 Your gas fire must have been commissioned by a Gas Safe registered installer evidence of which you must provide together with the Gas Safe registration number 3...

Отзывы: