background image

6 of 13 

 

Certification notes

 

 

 

Safety notes 

 

 

Danger:

 

Avoid direct contact with water or other fluids. Failure to do so may lead to 
incorrect functioning of the equipment or to personal injury.  

 

Danger:

 

Avoid exposure to extreme temperatures (see environmental conditions). 
Failure to do so may lead to incorrect functioning of the equipment or to 
personal injury. 

 

Warning:

 

Balancing of the arm is achieved with the aid of mechanical energy. If the 
arm slips out of the arm pad, mechanical energy will be released resulting 
in a fast-moving arm-fitting. This may result in physical injury (for more 
information, see page 9)    

 

Warning:

 

Do not make changes to any part of this equipment without the 
permission of the manufacturer. Failure to do so may lead to incorrect 
functioning of the equipment or to personal injury. 

 

Warning:

 

If the equipment is not functioning correctly, you should contact Focal 
immediately. Do not try to repair it yourself. Failure to observe this 
warning may lead to the termination of the warranty.  

 

Warning:

 

In case of doubt about safety, please contact Focal.  

Contact details 

Balancer is produced and sold by: 
 
Focal Meditech BV 
Droogdokkeneiland 19 
5026 SP Tilburg 
The Netherlands 
Tel.: 

 

+31 (0)88 119 31 3 

Tel.: 

 

+31 (0)88 119 50 4 

E-mail:   

[email protected] 

Internet: 

www.focalmeditech.nl

 

 

 

This is a CE class 1 medical device  

 

 

This label must not be removed. Removal of this label will 
result in termination of the warranty.  

Dutch Cliq classification: 

241827030309

 

Forearm supports, compensation of reduced muscle function 
and change in range of movement, support arm construction 

241827060309

 

Forearm supports, control of excessive muscle function, 
support arm construction 

241827090309

 

Forearm supports, redistribution of pressure/force, support 
arm construction 

241827990306

 

Forearm pad 

Содержание 872FOCPBLC00ABD187

Страница 1: ...User manual Identifier 872FOCPBLC00ABD187 Version 1 0 Date 28 06 2017 Balancer User manual...

Страница 2: ...Notice of Copyright Focal Meditech BV All rights reserved This manual may only be copied or used in accordance with the conditions of the purchase agreement for this product Except in situations prov...

Страница 3: ...cription 8 Adapting the arm balance 9 Adapting the balancing force 10 Folding and unfolding the Balancer 10 Assembly instructions 11 Maintenance instructions 11 Maintenance of physical components 11 C...

Страница 4: ...the best and safest use out of the dynamic arm support over the long term The information will tell you what you should and should not expect from the dynamic arm support how the device can be adjuste...

Страница 5: ...oint or to an authorised recycling centre for electrical and electronic equipment EEE Improper processing of this type of waste can have a negative impact on the environment and on public health resul...

Страница 6: ...onal injury Warning If the equipment is not functioning correctly you should contact Focal immediately Do not try to repair it yourself Failure to observe this warning may lead to the termination of t...

Страница 7: ...f learning to use Intended use of the device Balancer is a medical device Balancer can be used on one or both sides The device can be mounted on a wheelchair a chair or on a mobile base as required Du...

Страница 8: ...arm fitting at all times The cord is used to transfer the force from the spring mechanism to the arm fitting The horizontal arm brings the arm fitting into the working reach of the user Hinge 1 can b...

Страница 9: ...he more the wrist fitting is moved backwards i e towards the elbow the easier the arm and hand can be tilted downwards If the wrist fitting is moved forwards the arm and the hand can be tilted upwards...

Страница 10: ...e same procedure for the shaft on the horizontal rod The lever should only be pulled outwards to fix this in its optimum position after unfolding 2 Folding the Balancer Start by loosening the shaft on...

Страница 11: ...ntenance instructions Maintenance of physical components All housings and the cord must be inspected on a regular basis If these parts are visibly damaged the device should not be used It is not permi...

Страница 12: ...LC ABC091 Balancer complete 872FOCSABLC ABD291 Balancer complete Heavy duty means each number between 00 and 99 for internal use Focal have been classified as Class I according to Annex IX rule number...

Страница 13: ...are in accordance with the conditions of the national or local authorised representative This being in accordance with national legislation Conditions and warranty direct delivery by Focal Meditech BV...

Отзывы: