Installation and Operation Manual
AFC
FULL TIME REMOTE START/STOP
FEATURE
This feature was changed from a programmable
feature to a full-time feature. When using the
Remote Start/Stop module with the FoamPro 2000
or 3000 system, the Concentrate Management
System (CMS) can be operated at the same time.
The Remote Start/Stop module will operate and
install in the same manner as before, but it will not
be a programmable feature. The FoamPro AFC will
automatically recognize that this feature is being
used when the 4-pin cable is attached to the
receptacle on the back of the controller.
FULL TIME CONCENTRATE
MANAGEMENT SYSTEM FEATURE
This feature was changed from a programmable
feature to a full-time feature. The CMS module can
now be used concurrently with the Remote
Start/Stop feature without changing or setting the
defaults manually. When a CMS module is installed
to the FoamPro AFC, it will automatically recognize
that this feature is being used. The interface wiring
has changed for this feature and is described in this
manual. The CMS operation, set-up and calibration
will remain the same as with the standard FoamPro
system controller. When using this feature, you will
need to purchase the 2520-0091 CMS interface
cable.
The FoamPro Advanced Feature Digital Display
Control Module (AFC) is designed to add specific
options to the functionality of your 2000 or 3000
Series FoamPro System. Basic installation, setup,
calibration and operation are all the same as the
standard controller (Reference Forms 829, 836, 860,
903 and 904). The basic operation of the controller
remains the same as the standard controller with the
following added features:
AUTOMATIC “ON” FEATURE
This programmable feature allows the
operator to remotely power up the 2000 or 3000
FoamPro system directly into the “ON” mode. In this
mode, when power is supplied to the system, the
system is powered and ready for operation without
pressing the red “ON” button. There is an
approximate 5-second delay before system
operations will begin, which allows the system to run
the self diagnostics programming. When water flow
is present, the system will start to operate
automatically. The “ON” button, when depressed,
will turn the system on and off the same as the
standard controller.
An example of when this feature would be used is
when the operator always requires foam operations
from the initial setup of equipment. The system may
be powered up along with the engagement of the
apparatus pump PTO. This would allow the
FoamPro system to be active and running with the
first water flow to the discharge from the initial
engagement without adding extra operation
procedures for the engineer.
Another example of this type of operation would be
in conjunction with the engagement of the
compressor in a CAF system.