Foamit SP1.5L Скачать руководство пользователя страница 2

 Page 2 of 4   | 11162018

User Manual: 0.4 gallon (1.5 liter) Pump-Up Spray Unit | English

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

 Model Number: SP1.5L, SP1.5LBK and related units

Read this manual completely and understand the 

machine before operating or servicing it.

•  Read all instructions before installing or operating unit.
•  Always wear appropriate personal protective equipment 

(PPE) when operating or servicing unit.

•  Always follow all chemical safety precautions and 

handling instructions provided by the chemical 

manufacturer and Safety Data Sheet (SDS).

•  If this unit is modified or serviced with parts not listed in 

this manual, the unit may not operate correctly.

•  Never point the discharge wand at yourself, another 

person, or any object you do not want covered in 

chemical.

•  Never leave unit unattended while pressurized.
•  Always depressurize unit before attempting to remove 

the pump assembly.

•  Always depressurize unit after use (as described in the 

After Use Instructions). Always store unit depressurized.

•  Do not pressurize unit by any means other than the built-

in pump assembly.

•  Do not modify or remove pressure relief valve.  Do not 

use unit if pressure relief valve is not operational.

•  Always flush the unit with fresh water when switching 

from an alkaline to an acid or an acid to an alkaline.

•  Always carry unit by the carrying handle.  Never lift or 

carry the unit by the pump handle or the wand.  

•  Never use unit with hydrocarbons or flammable 

products.

•  Do not exceed a fluid temperature of 100˚F (37˚C).

WARNING

PROTECT THE ENVIRONMENT

Please dispose of packaging materials, old machine 

components, and hazardous fluids in an environmentally safe 

way according to local waste disposal regulations. 

Always remember to recycle.

*Specifications and parts are subject to change without notice.

REQUIREMENTS

Liquid temperature 

range

40-100˚F (4.4-37˚C)

Chemical compatibility Chemical products used with this 

equipment must be formulated 

for this type of application and 

compatible with unit materials and 

pump seals.  For more information 

on chemical compatibility, consult 

the manufacturer or SDS for your 

product or contact our customer 

service department.

SPECIFICATIONS

Power type 

Manual

Chemical pickup type

Draws from pre-mixed solution

Number of products 

unit can draw from

One product

Operating Capacity

0.3 gallon (1.1 liter)

Discharge wand/tip 

type

Adjustable cone nozzle that ranges 

from spray to stream

Output distance

1-8 ft (0.3-2.4 m) 

Output volume

10-26 oz/min

Pump seals

Viton

Run time on full tank

30 seconds to 1 minute and 45 

seconds, depending on nozzle setting