READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

 Model No.: FI-5N-SM, FI-5NK-SM, FI-5NV-SM AND RELATED UNITS

Read this manual completely and understand the 

machine before operating or servicing it.

• 

Read all instructions before installing or operating unit.

• 

Always wear appropriate personal protective equipment 

(PPE) when operating or servicing unit.

• 

Always follow all chemical safety precautions and 

handling instructions provided by the chemical 

manufacturer and Safety Data Sheet (SDS).

• 

If this unit is modified or serviced with parts not listed in 

this manual, the unit may not operate correctly.

• 

Never point the discharge wand at yourself, another 

person, or any object you do not want covered in 

chemical.

• 

Always keep the air trigger port clean and free of 

blockages or debris.  If the port becomes dirty or 

blocked, disconnect the compressed air source from 

the unit immediately and clean out the port before 

proceeding.

• 

Always keep the discharge hose free of kinks or 

obstructions. 

• 

Always rinse and drain unit after use (as described in the 

After Use Instructions).  Always store unit disconnected 

from the compressed air source.

• 

Do not exceed an incoming air pressure of 100 psi (7 

bar).

• 

Do not exceed a fluid temperature of 100˚F (37˚C).

• 

Always flush the unit with fresh water for 5 minutes 

when switching from an alkaline to an acid or an acid to 

an alkaline.

• 

Only use clean and dry air.  Air must be filtered and free 

of moisture or pump life will be diminished.  If needed, 

install a water separator (WS-20CFM) before the unit.

• 

Do not use an air lubricator before the unit.

WARNING

PROTECT THE ENVIRONMENT

Please dispose of packaging materials, old machine 

components, and hazardous fluids in an environmentally safe 

way according to local waste disposal regulations. 

 Always remember to recycle.

*Specifications and parts are subject to change without notice.

OPTIONS

Pump Seal Material

FI-5N

Santoprene (

standard

)

-SM

Viton 

(V)

Kalrez 

(K)

Add bold option codes to item number as shown.  For standard 

options, no option code is needed.
Examples:

• 

FI-5N-SM (standard unit with Santoprene pump seals)

• 

FI-5NV-SM (unit with Viton pump seals)

Содержание FI-5N-SM

Страница 1: ...USER MANUAL MODEL NUMBER FI 5N SM FI 5NK SM FI 5NV SM AND RELATED UNITS 5 Gallon Smart Foam Unit English Original Instructions ...

Страница 2: ...lways keep the discharge hose free of kinks or obstructions Always rinse and drain unit after use as described in the After Use Instructions Always store unit disconnected from the compressed air source Do not exceed an incoming air pressure of 100 psi 7 bar Do not exceed a fluid temperature of 100 F 37 C Always flush the unit with fresh water for 5 minutes when switching from an alkaline to an ac...

Страница 3: ...e Compressed air Chemical pickup type Draws from pre mixed solution Number of products unit can draw from One product Capacity 5 gallons 22 02 liters Discharge hose diameter length 20 ft 9 1 m bonded hose with 5 8 in 15 9 mm and 1 4 in 6 4 mm inside diameter Discharge wand tip type Ultra high molecular weight UHMW polyethylene handle and wand extension with 65 fan tip and built in zero tip Output ...

Страница 4: ...ut off and depressurize Foam that is already in the discharge hose may seep out but no more foam will be created until you cover the air trigger again After Use Instructions 7 Rinse the unit tank thoroughly with fresh water Then fill the tank with fresh water 8 Activate the unit and allow it to run for 2 4 minutes or until all chemical has been flushed from the system 9 Disconnect the air line fro...

Страница 5: ... problem persists the stainless steel mixing mesh SS MESH inside the tee fitting SST12HB38 could be plugged Remove and clean the mesh following the instructions below a Ensure that the unit has been flushed and disconnected from the air supply according to the After Use Instructions Also ensure that the unit tank is empty and or that the valve PVCV34FM at the base of the suction line is closed b R...

Страница 6: ...RE OPERATING EQUIPMENT Model No FI 5N SM FI 5NK SM FI 5NV SM AND RELATED UNITS TANK 5N TANK 5N HNDL CST5 WHL JC35B TANK ASSEMBLY ITEM NUMBER TANK 5N A SSC58 SSC14 HBSS1258 HBSS1814 SMH Air Trigger Port PW1238 ST65150SS WAND ASSEMBLY ITEM NUMBER SMWA DISCHARGE HOSE ASSEMBLY ITEM NUMBER H5814 20 ...

Страница 7: ...SM AND RELATED UNITS H38B H SST12HB38 SSC38 P56 P56K or P56V P56 BRKT P56 BRKT SCREW NV14Y AG100 R25 BPS 58SO BPS SSR SN1414 HBSSEL1438 P18 HBSSEL1438 H14B H CV38 Available per Available per HBBEL1414 HBSSEL1438 SM PV EC14 2 HBSS1438 BACK PLATE ITEM NUMBER PA PF SM HBSS1414 HBSS1258 FWP12 FWLG14 SSA14 TW916 BPS 58S0 AP25 NV14Y BACK PLATE Outside View ...

Страница 8: ...S P56 PUMP WITH SANTOPRENE SEALS INCLUDES HOSE BARBS AIR FITTING AND EXHAUST BARB P56K PUMP WITH KALREZ SEALS INCLUDES HOSE BARBS AIR FITTING AND EXHAUST BARB P56V PUMP WITH VITON SEALS INCLUDES HOSE BARBS AIR FITTING AND EXHAUST BARB P56 BRKT PUMP BRACKET STAINLESS STEEL P56 BRKT SCREW HI LO SCREW FOR RETAINING P56 BRKT PLPF PORTABLE FOAMER BACK PLATE W HINGE AND HOLES PLPF PIN 302 STAINLESS PORT...

Отзывы: