Model No.: FI-20N, FI-20NK, FI-20NV, FI-20N-ST, FI-20NK-ST, FI-20NV-ST
Specifications:
Hose ............ 30 feet reinforced hose, 3/4 inch inside diameter
(9 meters reinforced hose, 19 mm inside diameter)
Foam Output.................................... 20 to 45 gallons/minute
(75 to 170 liters/minute)
Foam Distances ............................... 25 to 30 feet (7 to 9 meters)
Liquid Temperature ........................ 40˚F to 100˚F (4.4˚C to 37˚C)
Noise Level...................................... Average 79 dB(A)
Discharge Wand Vibration Level ….. Maximum 2.5 m/s²
Dimensions:
Length ....................................... 22 in (559 mm) approximately
Width ........................................ 19 in (483 mm) approximately
Height ....................................... 47 in (1194 mm) approximately
Weight, including discharge hose and wand:
(Empty) ................................ 50 lbs (23 kg) approximately
(Full) ..................................... 223 lbs (101 kg) approximately
Requirements:
Compressed Air Pressure Requirements: Air regulator (R25)
factory set at 50 psi (3.4 bar). Operating range is 40 to 80 psi (3
to 5 bar) with 5 to 10 CFM (141.64 to 283.30 l/min)
Chemical requirements: follow all instructions from chemical
manufacturer.
Air Operated Double Diaphragm Pump Models Offered:
P56: Polypropylene body with Santoprene diaphragm
P56V: Polypropylene body with Viton diaphragm
P56K: Polypropylene body with Kalrez diaphragm
Acceptable Products:
Alkaline cleaners, Caustic cleaners, Sanitizers, and Acids
* D-Limonene may only be used with Kalrez pump
* Chlorine may only be used with Viton or Kalrez pump
DO NOT USE: All hydrocarbons
Read this manual completely and understand the
machine before operating or servicing it.
• Always wear protective clothing, gloves, and eyewear
while operating or servicing unit.
• Avoid contact of cleaning agent with skin and eyes.
If contact occurs, see SDS sheet for further first aid
measures.
• Read chemical’s Safety Data Sheet (SDS) before using this
unit.
• Never point the discharge wand at anyone.
• Incoming air pressure cannot exceed 100 psi (7 bar).
• After each use, relieve all remaining pressure in the
system by unplugging the air line from the unit and
opening the discharge ball valve to prevent accidental
discharge.
• After relieving the pressure from the unit, store the unit
with the ball valve in the closed position.
• Be sure to flush the unit with fresh water for 5 minutes
when switching from an alkaline to an acid or an acid to
an alkaline.
• Do not exceed a fluid temperature of 100˚F (37˚C).
• Only use clean and dry air. Air must be filtered and free
of moisture or pump life will be diminished. If needed,
install an air dryer before unit.
•
Do not use air lubricator before the unit.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine
components, and hazardous fluids in an environmentally safe
way according to local waste disposal regulations.
Always remember to recycle.
*Specifications and parts are subject to change without notice.
WARNING