04

:Turn all measurement parameters on / off

:Reduced vertical sensi /voltage measurement 

     range

:Vertical position / trigger level switching adjustment

:Short press-save the current waveform

     long press-you can view the saved waveform

:trigger

:Reduced horizontal time base

:stop

:menu

:confirm
:Back to center-press to select all, vertical offset, 

     trigger position, trigger level, back to center
:Increased horizontal time base
:Auto-center the measured unknown waveform 

    with the appropriate time base
:Latch the current waveform to the screen background

:Multiple switching

:Increased vertical sensitivity- / voltage measurement 

    

range

:AC-DC switching

OK

50%

s

AUTO

REF

X1X10

V

ACDC

MENU

STOP

ns

SINGLE

SAVE

SEL

mV

MEAS

Содержание FNIRSI-1C15

Страница 1: ...Oscilloscope FNIRSI 1C15 FNIRSI 1C15 is a full featured practical cost e ective handheld oscilloscope launched by FNIRSI FNIRSI...

Страница 2: ......

Страница 3: ...gefunction canstoreupto81pictures Referencewaveform youcanpausetosavetheprevious frame waveform to the screen at any time and you cancompareitwiththecurrentlyrefreshedwaveform Afterglowandscrollmodesm...

Страница 4: ...g YT scroll None 1s 5V 800mA One button automatic Waveform measurement measurement accuracy Reference waveform Waveform save Frequency accuracy Input resistance Single triggerc 50 back to middle Opera...

Страница 5: ...gger position Normal display interface Move the joystick left or right to move the horizontal time base Press the MENU button to open the interface The joystick moves up and down to switch the categor...

Страница 6: ...rizontal time base stop menu con rm Back to center press to select all vertical o set trigger position trigger level back to center Increased horizontal time base Auto center the measured unknown wave...

Страница 7: ...fullycharged Themaximumcharging voltage is 7V if you use a mobile phone to fast charge the charging head voltage may exceed this voltage please do not use it 2 Vertical time base scale Press the mv an...

Страница 8: ...ys to expand and contract the waveform You can also move the waveform left or right by using the joystick Click the Stop button in stop mode to make the oscilloscope enter the running state Stop run s...

Страница 9: ...lloscope will perform the operation according to the corresponding item 6 Single single trigger Single trigger means that after pressing the button the oscilloscope samples a frame of waveform and the...

Страница 10: ...oscope and then click single the oscilloscope is in the wait state because there is no waveform at this time and then power on the circuit under test the waveform cross domain trigger level generated...

Страница 11: ...thenlockthewaveform on the screen and then move the probe to measure the other Mos tube so two driving waveforms can be displayed on the screen at the same time for easy comparison Inthe running stat...

Страница 12: ...rm graph selected by the red focus frame Click the button OK key corresponding to the Zoom In Zoom Out icon to zoom in the waveform selected by the red focus frame After zooming in click any key to re...

Страница 13: ...eak positivedutycycle amplitude positive amplitude negative amplitude maximum minimum period root mean square average positive pulse width negative pulse width negative duty cycle Introduction to meas...

Страница 14: ...o upgrade and optimize the product software After that we will release our latest rmware in our o cial store 1 Click the SEL button immediately after power on the oscilloscope interface displays Engli...

Страница 15: ...obe correctly and make sure that the measured voltage does not exceed the maximum withstand voltage Connect the probe correctly Before measuring voltage greater than 40V please switch the probe to the...

Страница 16: ...http www fnirsi cn...

Отзывы: