14. SWR Warning
When the SWR value goes beyond the limit, the transmitter will switch on protection
automatically and stop broadcasting. Please solve the problems following our Problem solving
guide and restart the transmitter. Or press
【
】
to the home page, in this case the power will
automatically decrease to 1watt and you can start setting.
SWR Warning page
Attention: If the transmitter is working above 1watt, please use outdoor antenna.
15. Over-heat Warning
When the working temperature of the transmitter goes too high, the protection will be
automationcally turned on, the transmitter will stop broadcasting. You can solve the problem
following our problem solving guide, then restart the transmitter.
Over-heat warning page
16.SWR and Temperature Protection Setting
Press and hold the
【
←
】
button, then connect the power supply, release the button to enter in
protection setting page.
Protection Setting Page
(
1
)
SWR protection
In the protection setting page, press
【
▲
】
button to enter in SWR protection setting page,
press
【
▲
】
or
【
▼
】
to set the value between 2.5~4.0, then press
【
】
button to go back to
protection setting page. Press
【
】
again to exit. The transmitter stays in working status.
SWR protection setting page