CHAPTER 2 Safety Instruction and Installations 

Safety Instructions 

WARNING: Hot plug is not allowed since it may cause system halted. 

To prevent fire or electrical shock, do not expose the device to rain or moisture. 

 

  The encoder modulator is powered with a voltage of 12V DC. The power supply voltage 

must not exceed the recommended voltage, which otherwise may cause irreparable damage to 

the device and the invalidation of the warranty. Therefore:   

l

 

Do not replace power supply with a voltage greater than 12V DC.   

l

 

Do not connect the device to the power if the power cord is damaged.   

l

 

Do not plug the device into mains supply until all cables have been connected correctly.   

l

 

Do not cut the cord.   

Avoid  placing  the  device  next  to  central  heating  components  and  in  areas  of  high 

humidity.   

Do not cover the device with elements that obstruct the ventilation slots.   

If the encoder modulator has been kept in cold conditions for a long time, keep it in a warm 

room minimum 2 hours before plugging into the mains.   

Mount the device in vertical position with the connectors located on the top side.   

When  replacement  parts  are  required,  be  sure  the  service  technician  has  used  replacement 

parts  specified  by  the  manufacturer  or  have  the  same  characteristics  as  the  original  part. 

Unauthorized substitutes may result in fire, electric shock or other hazards. 

Safety  check-  Upon  completion  of  any  service  or  repairs  to  this  device,  ask  the  service 

technician to perform safety checks to determine that the device is in proper condition. 

Installations 

RISK of damage to the unit 

Mechanically  handling  the  unit  may  result in  damage.  Do  not  connect  the  unit to  the  power 

supply before or during assembly. Connect the unit as below instructed.   

NO HOT PLUG AND CONNECT THE 

CABLE AS FOLLOWING STEPS.   

1.

 

Mount  and  tighten  the  screws  and  plugs 

to secure the unit to the wall. Left 10 cm 

of free space around from each unit.

 

 

 

1

Содержание FUTV4622

Страница 1: ...F MU S E RI NT E R NA T I ONA LG R OU PI NC 1 14 FUTV4622 DVB T Encoder Modulator with USB H o m e U s e User Manual...

Страница 2: ...in the best conditions of performance Keep this manual for future reference Directory CHAPTER 1 Product Introductions 3 General Description 3 Working Principle 3 Technical Specifications 4 CHAPTER 2 S...

Страница 3: ...ance control hotel Digital Signage shops etc It is an all in one device integrating MPEG 4 AVC H 264 encoding and modulating to convert audio video signals into DVB T RF out The signals source could b...

Страница 4: ...Ratio 16 9 4 3 Bit rate 1 000 18 000 Mbps Audio Encoding MPEGI layer 2 Sample rate 48KHz Bit rate 64 96 128 192 256 320kbps DVB T Modulator Section Standard DVB T COFDM Bandwidth 6M 7M 8M Constellati...

Страница 5: ...that obstruct the ventilation slots If the encoder modulator has been kept in cold conditions for a long time keep it in a warm room minimum 2 hours before plugging into the mains Mount the device in...

Страница 6: ...onnect the earth cable b Connect the power plug to the unit mains connector c Connect the power plug to the mains socket Cascade Installation FUTV4622 unit has 1 TV signal to RF output encoded as DVB...

Страница 7: ...F MU S E RI NT E R NA T I ONA LG R OU PI NC 7 14 Typical Applications...

Страница 8: ...nge the parameter settings in the program mode Enter Use this button to enter a submenu or save a new setting after adjustment press it to start adjusting the value of certain items with Up Down butto...

Страница 9: ...C Guard Interval 1 32 FEC 7 8 15 Main Menu System System Save Config System Load Saved CFG System Lock Keyboard System Product ID System Version Save Config Yes No Load SavedCFG Yes No Lock Keyboard Y...

Страница 10: ...here are three options Default Australia or New Zealand If user chooses Default modulating parameters need to be set manually through advanced configuration If choose other two user do not need to set...

Страница 11: ...s seconds 20 Key Password to set a 6 digit password for unlocking the keyboard 21 Lock Keyboard Choose Yes to lock the keyboard then the keyboard will be locked and cannot be applicable It is required...

Страница 12: ...oder modulator is embedded with USB Port for upgrading The supported file format is IMG Upgrade steps Insert USB device Upgrade automatically It will need 10 20 seconds to upgrade After upgrade FUTV46...

Страница 13: ...694 697 5 701 C11 216 219 5 223 C53 701 704 5 708 C12 223 226 5 230 C54 708 711 5 715 C55 715 718 5 722 UHF C56 722 725 5 729 C57 729 732 5 736 C20 470 473 5 477 C58 736 739 5 743 C21 477 480 5 484 C...

Страница 14: ...04 8 70 9 67 10 24 10 55 9 95 11 06 11 71 12 06 2 3 9 95 11 05 11 70 12 06 11 61 12 90 13 66 14 07 13 27 14 75 15 61 16 09 3 4 11 19 12 44 13 17 13 57 13 06 14 51 15 36 15 83 14 93 16 59 17 56 18 10...

Отзывы: