5. Disassembly
Disassembling the pump
Condition:
The pump is switched off.
1.
Disconnect the main plug.
2.
Release the delivery hose (15) from the pressure union at the pump (13).
3.
Unscrew the pump from the thread of the fuel container.
4.
Slowly remove the pump with the suction hose (6) and the suction pipe (8). Let all diesel
or heating fuel run out completely from the suction hose and suction pipe.
5.
Place the pump with hoses in an oil tray.
6.
Let the emerging fuel oil or diesel run into the oil tray.
6. Maintenance
The
PREMA
xx
electrical pump is in principle low maintenance and low service.
Due to the operator duty according to § 191 WHG, the following parts of the pump must be
checked regularly to avoid environmental damage being caused by emerging fuel oil or
diesel:
•
Pump housing (1)
•
Delivery hose (15)
•
Nozzle (9 or 17)
In case of any damage the connecting cable has to be replaced or repaired by the
manufacturer, by the manufacturer’s service or by any other qualified person.
7. Repair / Service
The
PREMA
xx
electrical pump has been developed and manufactured according to the
highest quality standards.
If a problem should arise in spite of all quality measures, please contact our
FMT Swiss AG
Tel +49 7665 9346 105
Fax +49 7665 9346 120
[email protected]
10