Operating Manual CMGZ100
5
2.5
Controller release
The CMGZ100 Tension Controller can be released over a digital input (12-30V AC or DC). As long as there is
no signal the Tension Controller is locked and the output is zero. When the voltage is applied the Tension
Controller starts operating and the output signal goes from zero to the required value that is needed for the
desired tension.
2.6
Limit switches
The CMGZ100 provides a minimum switch (GW1) and a maximum switch (GW2). If the threshold is overrun
the appropriate front-mounted LED lights up and a relay switches on (24V, 0.5A). The thresholds are being set
with front-mounted 10-turn potentiometers R3 ad R4.
The threshold value can be measured at pin X4 and X5.
The relay outputs are available on the connerctor at z14/z16 and d14/d16.
2.7
Overlaid line speed
If the Tension Controller is used in a line drive application the dynamic can be increased by using an available
line speed signal, which is fed to the Tension Controller. The tension control loop then is only responsible for
the correction of this signal. By setting jumper X24 to X25 the part of this overlaid controller signal can be
adjusted.