INSTALLATION
Continued
14"
Min.
Combustible
Material
Noncombustible Material
Hearth
5"
Min.
Combustible
Material
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
Area of Various Standard Round Flues
Diameter
Area
5"
20 sq. inches
6"
29 sq. inches
7"
39 sq. inches
8"
51 sq. inches
Chimney
Height
Minimum Permanent
Flue Opening
6' to 15'
39 sq. inches
15' to 30'
29 sq. inches
INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION
Note: When used as a vented heater, ap-
pliance must be installed only in a solid-fuel
burning fireplace with a working flue and
constructed of noncombustible material.
You may use this heater as a vented product.
There are three reasons for operating your
heater in the vented mode.
1. The fireplace does not meet the clear-
ance to combustibles requirements for
vent-free operation.
2. State or local codes do not permit vent-
free operation.
3. You prefer vented operation.
If reasons number 1 or 2 apply to you, you
must permanently open chimney flue damper.
You must install the damper clamp accessory
(to order, see
Accessories
, page 31). This
will insure vented operation (see Figure 10).
The damper clamp will keep damper open.
Installation instructions are included with
clamp accessory.
See chart below for minimum permanent flue
opening you must provide. Attach damper
clamp so the minimum permanent flue open-
ing will be maintained at all times.
Figure 10 - Attaching Damper Clamp
Manufactured
Fireplace
Masonry Fireplace
Damper
Damper
Clamp
Damper
Damper
Minimum
Noncombustible
Material
8"
Min.
12" 15" 18" 20"
2½"
6"
8"
10"
12"
Distances to
Underside of
Mantel
Hood
(GA6050 or
GA6053)
Top of
Fireplace
Opening
Underside
of Mantel
Shelf
Mantel Shelf
Figure 7 - Minimum Mantel Clearances