background image

www.fmiproducts.com

125790-01B

3

 WARNING: Do not allow fans 

to blow directly into the fireplace. 

Avoid any drafts that alter burner 

flame patterns. Ceiling fans can 

create  drafts  that  alter  burner 

flame  patterns. Altered  burner 

patterns can cause sooting.

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable material on or near 

the appliance. Never place any 

objects on the heater.

Heater base assembly becomes 

very hot when running heater. 

Keep children and adults away 

from hot surface to avoid burns 

or  clothing  ignition.  Heater 

will remain hot for a time after 

shutdown. Allow surface to cool 

before touching.

Carefully supervise young chil

-

dren when they are in the room 

with heater.

You  must  operate  this  heater 

with  the  fireplace  screen  and 

hood  in  place.  Make  sure  fire

-

place  screen  and  hood  are  in 

place before running heater.

Keep  the  appliance  area  clear 

and  free  from  combustible 

materials,  gasoline  and  other 

flammable vapors and liquids.

 WARNING: This product con

-

tains and/or generates chemicals 

known to the state of California 

to cause cancer or birth defects 

or other reproductive harm.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before trying to assemble, op

-

erate  or  service  this  fireplace. 

Improper  use  of  this  fireplace 

can  cause  serious  injury  or 

death  from  burns,  fire,  explo

-

sion, electrical shock and carbon 

monoxide poisoning.

 DANGER: Carbon monoxide 

poisoning may lead to death!

Carbon Monoxide Poisoning: 

Early signs of 

carbon monoxide poisoning resemble the flu, 

with headaches, dizziness or nausea. If you 

have  these  signs,  the  fireplace  may  not  be 

working properly. 

Get fresh air at once!

 Have 

fireplace serviced. Some people are more af

-

fected by carbon monoxide than others. These 

include pregnant women, people with heart or 

lung disease or anemia, those under the influ

-

ence of alcohol and those at high altitudes.
Natural and Propane/LP gases are odorless. An 
odor-making agent is added to these gases. 
The odor helps you detect a gas leak. How-

ever, the odor added to the gas can fade. Gas 

may be present even though no odor exists.
Make certain you read and understand all 
warnings. Keep this manual for reference. It 
is your guide to safe and proper operation of 

this fireplace.

  WARNING:  Any  change  to 

this heater or its controls can 

be dangerous.

 WARNING: Do not use a 

blower  insert,  heat  exchanger 

insert or other accessory not ap

-

proved for use with this heater. 

SAFETY

Continued

Содержание TF18NE

Страница 1: ......

Страница 2: ......

Страница 3: ...h defects or other reproductive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op erate or service this fireplace Improper use of this fireplace can cause serious injury or death from burns fire explo sion electricalshockandcarbon monoxide poisoning DANGER Carbonmonoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide po...

Страница 4: ... To prevent the creation of soot follow the instructions in Cleaning and Maintenance page 34 9 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated thevaporsfromtheseproductsmay create a white powder residue within burner box or on adjacent walls and furniture 10 This heater needs fresh outside air ven tilation to run properly This heater has an Oxygen Dep...

Страница 5: ......

Страница 6: ...Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from the house to operate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are excerpts from...

Страница 7: ...200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free fireplace ___________ Btu Hr Gas water heater ___________ Btu Hr Gas furnace ___________ Btu Hr Vented gas heater ___________ Btu Hr Gas fireplace logs ___________ Btu Hr Other gas appliances __________ Btu Hr Total __________ Btu Hr Do not include direct vent gas appliances Direct vent ...

Страница 8: ......

Страница 9: ...moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventila tion page 6 CHECK GAS TYPE Use the correct type of gas natural or propane LP If your gas supply is not the correct gas type do not install heater Call dealer where you bought heater for proper type heater WARNIN...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...The system will not function under 3 8 volts and bat teries should be replaced if the voltage is under 4 0 volts 2 Plug power supply box to module see page 15 3 Plug touch pad in module see page 16 figure 19 Check to see it is positioned as shown 4 Check to see that the control valve wiring harness blue connector is plugged in to the module Check to see that it is aligned with the ma ing pins If a...

Страница 37: ...by any metal or tubing Keep ignitor cable dry 9 Replace wire harness including ignitor cable 10 Replace ods pilot assembly 11 Replace ods pilot assembly 12 Replace control module 13 Ground cable from control valve wiring harness is not ground ing properly Reposition spade terminal so that it makes contact with burner chassis metal or valve body 14 Change batteries in remote Check reception of sign...

Страница 38: ...uld be hand tight plus 1 4 to 1 2 turn You should not be able to loosen the thermocouple at the control valve with your hand Check the thermocouple terminal connection at the control module If it is loose remove it with needle nose pliers using he pliers slightly close the terminal s opening and reinstall on to he control module 4 While the pilot is sparking check for gas flow at the ods pilot If ...

Страница 39: ...rt in touch pad wiring BUT TON ERROR is shown in remote display 1 Batteries are weak LOW BAT TERY is shown in remote display 1 Fully open equipment shutoff valve 2 Check batteries and replace if needed Batteries in the power supply box can be tested wi h a multimeter at the two connections at the back of the battery housing where the red and black wires are connected Set the multimeter to DC volta...

Страница 40: ...TY temperature setting in the remote has shut the burner system off 1 More than one burner system is present and operating on the same frequency 1 Replace control module 1 Follow Re Pairing instructions on page 16 to re pair remote to control module 2 Replace control module 1 Either the remote is too far from the burner system or the remote needs new batteries The remote should work within 20 feet...

Страница 41: ...an burner see Cleaning and Maintenance page 34 or replace burner orifice 2 Replace damaged burner 3 Replace gas regulator 1 Checkburner s fordirtanddebris If found cleanburner s seeCleaning and Maintenance page 34 2 Replace gas regulator 1 Problem will stop after a few hours of opera ion 1 Set the unit to LO by using the remote and let warm up for a minute 2 Operate burners until air is re moved f...

Страница 42: ...ed 1 Gas leak See Warning state ment at top of page 2 Control valve or gas control defec ive 1 Foreign matter between control valve and burner 2 Gas leak See Warning state ment at top of page 1 Optional Hand held remote con trol is too close to heater REMEDY 1 Open window to ven ilate room Stop using odor causing products while heater is running 2 Refill supply tank propane LP only 3 Locate and co...

Страница 43: ......

Страница 44: ...www fmiproducts com 125790 01B 44 PARTS REMOTE MODELS TF18NE TF18PE TF2430NE TF2430PE 8 7 6 5 3 2 1 22 21 20 19 18 17 14 25 13 12 11 10 10 9 24 15 16 23 26 4 ...

Страница 45: ......

Страница 46: ......

Страница 47: ...r Crossover Log 8 1 9 125538 01 125538 01 125538 01 Switch Log 1 PARTS LOG SETS FOR MODELS LTF18 MO LTF24 MO LTF30 MO This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 43 of this manual 2 6 3 4 9 1 7 8 5 Each log includes reference numbers formed in the bottom or back of the log The circled number indicates t...

Страница 48: ......

Страница 49: ......

Страница 50: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 51: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 52: ......

Отзывы: