background image

www.fmiproducts.com

125701-01A

6

Figure7 - Lineal Gain

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

Georgian

Fireplace

66 

1

/

2

"

12-12DM

12-12HT

Pipe Section

10 

5

/

8

"

18-12DM

18-12HT

Pipe Section

16 

5

/

8

"

24-12DM

24-12HT

Pipe Section

23 

5

/

8

"

36-12DM

36-12HT

Pipe Section

34 

5

/

8

"

48-12DM

48-12HT

Pipe Section

46 

5

/

8

"

RLT-12D

RLT-12HT Round Termination

3

/

4

"

*

STL-12D Square Chase-Top 

with Slip Section

7"

 to 15

"

*

* The lineal gain for the terminations is mea

-

sured to the flue gas outlet height.

Hemmed 

End

12 

3

/

8

Stainless 

Inner Pipe

15" Galvanized 

Outer Pipe

ASSEMBLY AND INSTALLATION OF 

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of a 

galvanized outer pipe, a stainless steel inner flue 

pipe and a wire spacer. The pipe sections must 

be assembled independently as the chimney is 

installed. When connecting chimney directly to 

the fireplace, the inner flue pipe section must 

be installed first with the lanced side up. The 

outer pipe section can then be installed over 

5 the flue pipe section with the hemmed end 

up. Press down on each pipe section until the 

lances securely engage the hem on the fireplace 

starter. The wire will assure the proper spacing 

between the inner and outer pipe sections.

Figure 6 - Outside Air Kit

Secure to Collars with Metal Tape, 

Screws or Straps (Min. of 1/4" x 20" 

in size)

Air Inlet 

Location 

Must Allow 

For Bushes 

or Snow

Vent Hood 

Required for 

Wall Installation

Air Inlet 

Eyebrow

Vented Crawl Space

(Check Local Codes 

Before Installing in a 

Vented Crawl Space)

CHIMNEY PIPE

The FMI PRODUCTS, LLC chimney system 

consists of 12", 18", 24", 36" and 48" snap-

lock,  double-wall  pipe  segments,  planned 

for  maximum  adaptability  to  individual  site 

requirements. Actual  lengths  gained  after 

fitting overlaps must be taken into consider

-

ation (lineal gain) and are given in the lineal 

gain chart (see Figure 7). Lineal Gain is the 

actual measurable length of a part after two or 

more parts are connected. For Canada, use 

chimney parts designated "HT".

VENTING INSTALLATION

OPTIONAL OUTSIDE AIR KIT 

(MODEL AK4/AK4F)

The  installation  of  an  outside  air  kit  should 

be  performed  during  the  rough  framing  of 

the fireplace due to the nature of it's location. 

Outside combustion air is accessed through 

a  vented  crawl  space  (AK4F)  or  through  a 

sidewall (AK4).

  CAUTION:  Combustion  air 

inlet ducts shall not terminate 

in attic space.

The  maximum  height  for  the 

air vent can not exceed 3 feet 

below the flue gas outlet of the 

termination.

 WARNING: The opening in 

the collar around the chimney at 

the top of the fireplace must not 

be obstructed. Never use blown 

insulation  to  fill  the  chimney 

enclosure.

Содержание GMCAT50A Series

Страница 1: ...n how to install and maintain your appliance it also contains information that will enable you to obtain re placement parts or accessory items when needed Keep it with your other important papers This...

Страница 2: ...have beenevaluatedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use Thisfireplaceisnotintendedtobe used as a substitute for a furnace to hea...

Страница 3: ...0 MODELS 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSIDE AIR ACCESS 50 HEARTH 1 1 4 23 Ref 49 3 8 34 3 8 21 3 4 Figure 1 50...

Страница 4: ...er a location where fireplace will not be affected by drafts air conditioning ducts windows or doors 3 A location that avoids cutting of joists or roof rafters will make installation easier 4 An outsi...

Страница 5: ...arth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material see Figure 4 WARNING Hearthextension is to be installed only as shown in Figure 4...

Страница 6: ...ns Figure 6 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inl...

Страница 7: ...pipe sections are locked to gether When installing double wall snap lock chimney together it is important to assure the joint between the chimney sections is locked Check by pulling chimney upward af...

Страница 8: ...igure 12 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 PENETRATING ROOF To maintain a 2 cl...

Страница 9: ...ecure in position by nailing through shingles see Figure 14 DO NOT NAIL THROUGH FLASHING CONE Storm Collar Installation SC2 1 Place storm collar over pipe and slide down until it is snug against the o...

Страница 10: ...2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 18 10 Foot Rule Terminations Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations In any ca...

Страница 11: ...g Brackets 2 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of each firebrick wall Angle the wall into the fireplace opening and into the slots on the side of...

Страница 12: ...ing Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints where two firebr...

Страница 13: ...UCTS LLC grate only see Parts page 20 This grate has been de signed to keep the operation of yourfireplacesafeandefficient FIREBRICK WALL INSTALLATION Continued Figure 24 Installing Grate Retainers IN...

Страница 14: ...n apply soap and water solution to all connectionsandjoints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER ATEANYAPPLIANCE IFALEAK IS D...

Страница 15: ...ositionandtheglassdoors mustbeinthefullyopenposition OPTIONAL GAS LINE INSTALLATION Continued PUREFIRE HOOD INSTALLATION 1 The PureFire hood supplied with this fire place is packaged in a separate box...

Страница 16: ...d Slide Top Pins Into Track Figure 31 Adjusting Bi Fold Doors DOOR ADJUSTMENT Remove doors and slightly loosen lower pivot clips and upper spring clips Replace doors and fully close them Use 1 8 shims...

Страница 17: ...als as pitch wax laden logs very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace Always keep the fire we...

Страница 18: ...dustrial solvents flammable liquids naptha household garbage material treated with petroleum products leaves paper products cardboard or salt driftwood MANUFACTURER FMI Products LLC MODEL NO GCAT 50 P...

Страница 19: ...burned If visible smoke continues the combustor has ceased to function or there is thermal crumbling Call FMI PRODUCTS LLC at 1 866 328 4537 for replacement parts WARRANTY FMI PRODUCTS LLC warranty ob...

Страница 20: ...www fmiproducts com 125701 01A 20 PARTS MODELS V GMCAT50 H S I R A SERIES AND V JMCAT50 H S I R A SERIES 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28...

Страница 21: ...19 123298 02 Ash Box Assembly 1 20 Inner Dome Assembly 1 21 Smoke Shield 1 22 Damper Control Bracket 1 23 109457 01 Screen 50 2 117556 01 Screen 50 Stainless 2 24 110146 02 Screen Rod 50 2 117568 01 S...

Страница 22: ...www fmiproducts com 125701 01A 22 PARTS MODELS V GMCAT50 H S I R A SERIES AND V JMCAT50 H S I R A SERIES Picture may vary from actual 1 6 4 8 7 3 2 5 7 7 7 8 9...

Страница 23: ...02 Right Stacked 50 Ivory 1 125451 02 Right Herringbone 50 Ivory 1 6 125441 01 Left Stacked 50 Red 1 125453 01 Left Herringbone 50 Red 1 125441 02 Left Stacked 50 Ivory 1 125453 02 Left Herringbone 5...

Страница 24: ...g please have your model and se rial numbers of your fireplace ready You can also visit our web site at www fmiproducts com REPLACEMENT PARTS If this product is missing a part or has a broken componen...

Страница 25: ...ROOF FLASHING V6F 10DM 0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch ACCESSORIES Continued SQUARE CHASE TOP TERMINATION STL 12D AND STL 12DMP BLACK ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT STORM C...

Страница 26: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____...

Страница 27: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____...

Страница 28: ...125701 01 Rev A 03 11 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com...

Отзывы: