OPERATION AND MAINTENANCE GUIDELINES

GLASS DOORS

Glass  doors  are  optional  with  the  fireplace. 

When fireplace is in operation, doors must be 

fully opened or fully closed position only or a fire 

hazard may be created (see Figure 33).
A fireplace equipped with glass doors operates 

much differently than a fireplace with an open 

front. A fireplace with glass doors has a limited 

amount of air for combustion.
Excessive heat within the fireplace can result if 

too large a fire is built or if combustion air gate 

is not completely open. The following tips should 

be followed to assure that both the fireplace 

and glass door retain their beauty and function 

properly. Both the flue damper and glass doors 

must be fully opened before starting fire. This will 

provide sufficient combustion air and maintain 

safe temperatures in firebox.

IMPORTANT:

 The glass must be allowed to 

warm slowly and evenly. The tempered glass will 

withstand a gradual temperature rise to 550° F, 

which is more than a normal fire will generate. 

Such materials as pitch/wax laden logs, very dry 

mill end lumber and large amounts of paper or 

cardboard boxes can create an excessively hot 

fire and should not be burned in this fireplace. 

Always keep the fire well back from the doors 

and never allow flames to contact the glass.

  WARNING:  Fireplaces 

equipped  with  glass  doors 

should  be  operated  only  with 

doors fully opened or doors fully 

closed. Doors, if left partly open, 

may draw gas and flame out of 

the  fireplace  opening  creating 

risks of both fire and smoke.

Cleaning Glass

Clean glass with any commercial glass cleaner 

or soap and water. Do not use any abrasive 

material to clean glass. Do not clean glass with 

any cool water if glass is still hot from the fire 

and smoke.

Figure 33 - Bi-Fold Glass Doors

Doors Fully Closed

Fireplace Front

Doors

Fully Opened

Fireplace Front

OUTSIDE AIR AND DAMPER 

HANDLE OPERATION

The damper handle, which opens and closes 

the damper blade, is located in the upper front 

face of the fireplace. Pushing the handle for

-

ward and up through the keyway slot will free 

damper blade to automatically open. Pushing 

the handle forward and down will lock damper 

blade closed (see Figure 34).

Figure 34 - Operating Damper Handle

Damper 

Weight

To Close 

Damper

To Open 

Damper

Damper 

Weight

Содержание GMCAT42 Series

Страница 1: ...to install and maintain your appliance it also contains information that will enable you to obtain re placement parts or accessory items when needed Keep it with your other important papers This fire...

Страница 2: ...have beenevaluatedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use Thisfireplaceisnotintendedtobe used as a substitute for a furnace to hea...

Страница 3: ...22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17 5 8 67 61 49 7 1 30 11 58 42 51 1 8 4 1 2 3 1 2 9 1 2 10 1 2 81 2 13 17 OUTSIDE AIR ACCESS GAS LINE ACCESS 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8 21 3 4 Figure 1 42...

Страница 4: ...0 MODELS 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSIDE AIR ACCESS 50 HEARTH 1 1 4 23 Ref 49 3 8 34 3 8 21 3 4 Figure 2 50...

Страница 5: ...by drafts air conditioning ducts windows or doors 3 A location that avoids cutting of joists or roof rafters will make installation easier 4 An outside air kit is available with this fireplace see Opt...

Страница 6: ...arth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material see Figure 5 WARNING Hearthextension is to be installed only as shown in Figure 4...

Страница 7: ...ns Figure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inl...

Страница 8: ...pipe sections are locked to gether When installing double wall snap lock chimney together it is important to assure the joint between the chimney sections is locked Check by pulling chimney upward af...

Страница 9: ...igure 13 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 PENETRATING ROOF To maintain a 2 cl...

Страница 10: ...Secure in position by nailing through shingles see Figure 15 DO NOT NAIL THROUGH FLASHING CONE Storm Collar Installation SC2 1 Place storm collar over pipe and slide down until it is snug against the...

Страница 11: ...2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 10 Foot Rule Terminations Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations In any ca...

Страница 12: ...g Brackets 2 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of each firebrick wall Angle the wall into the fireplace opening and into the slots on the side of...

Страница 13: ...ng Place a wet towel over the bucket making sure it is directly on the surface of grout mixture This will keep the mixture moist and it will not dry out before use 5 Grout all joints where two firebri...

Страница 14: ...UCTS LLC grate only see Parts page 22 This grate has been de signed to keep the operation of yourfireplacesafeandefficient FIREBRICK WALL INSTALLATION Continued Figure 25 Installing Grate Retainers IN...

Страница 15: ...n apply soap and water solution to all connectionsandjoints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER ATEANYAPPLIANCE IFALEAK IS D...

Страница 16: ...lassdoors mustbeinthefullyopenposition OPTIONAL GAS LINE INSTALLATION Continued PUREFIRE HOOD INSTALLATION 1 The PureFire hood supplied with this fire place is packaged in a separate box and placed in...

Страница 17: ...on on door adjustment Figure 31 Installing Bi Fold Doors Spring Clip Insert Pin into Spring Clip Pivot Hole Insert Bottom Pivot Pin into Hole Fold Door and Slide Top Pins Into Track Figure 32 Adjustin...

Страница 18: ...als as pitch wax laden logs very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace Always keep the fire we...

Страница 19: ...d with petroleum products leaves paper products cardboard or salt driftwood Refer to your FMI PRODUCTS LLC Home owner s Guide included with your fireplace for proper fire building technique and ash re...

Страница 20: ...those models that have not met this emissions level Exposure to smoke has been associated with respiratory illness and other health problems Models that have lower smoke emissions may reduce your risk...

Страница 21: ...LACEMENT PARTS If this product is missing a part or has a broken component please do not return it to the store Call FMI PRODUCTS LLC at 1 866 328 4537 to answer questions and replace parts under warr...

Страница 22: ...www fmiproducts com 125701 01C 22 PARTS MODELS V GMCAT42 50 H S I R A SERIES AND V JMCAT42 50 H S I R A SERIES 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30...

Страница 23: ...Dome Assembly 1 21 Smoke Shield 1 22 Damper Control Bracket 1 23 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 24 110146 03 Screen Rod 42...

Страница 24: ...www fmiproducts com 125701 01C 24 PARTS MODELS V GMCAT42 50 H S I R A SERIES AND V JMCAT42 50 H S I R A SERIES Picture may vary from actual 1 6 4 8 7 3 2 5 7 7 7 8 9...

Страница 25: ...25439 02 Right Stacked 50 Ivory 1 125427 02 Right Herringbone 42 Ivory 1 125451 02 Right Herringbone 50 Ivory 1 6 125417 01 Left Stacked 42 Red 1 125441 01 Left Stacked 50 Red 1 125429 01 Left Herring...

Страница 26: ...50E 50 Ebony BDMO50G 50 Pewter BDMO50C 50 Oiled Bronze DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12DM 12 12HT 18 12HT 24 12HT 36 12HT and 48 12HT 30 OFFSET AND RETURN 30E 12DM and 30E 12HT O...

Страница 27: ...ROOF FLASHING V6F 10DM 0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch ACCESSORIES Continued SQUARE CHASE TOP TERMINATION STL 12D AND STL 12DMP BLACK ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT STORM C...

Страница 28: ...125701 01 Rev C 09 13 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com...

Отзывы: