background image

9

901846

OWNER’S MANUAL

INSTALLATION

Continued

Figure 8 - Kit Assembly

HEARTH KIT ASSEMBLY
AND INSTALLATION

Kit Assembly

Note:

 Be sure all pipe threaded connections

are tight, and have thread compound to
prevent leaks.

1.

Remove burner inlet fitting from front
burner (installed in burner pan, see Fig-
ure 8).

2.

Make sure ports on front burner are
facing the front (open side) of burner
pan. Refit if needed.

3.

Using thread sealant (resistant to the
action of propane/LP gas) on larger end
of fitting, screw the burner inlet fitting
through the hole and into the front burner
(see Figure 8). Tighten using a 7/8"
wrench. If using propane/LP gas, see
Propane/LP Gas Conversions, page 10.

4.

Apply thread sealant compound to the
3/8" male threads of the burner inlet
fitting. Thread the manifold block (see
Figure 8) onto the burner inlet fitting.
Use the bottom hole of the block.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)

1.

Close equipment shutoff valve (see Fig-
ure 7).

2.

Pressurize supply piping system by either
using compressed air or opening main gas
valve located on or near gas meter.

3.

Check all joints from gas meter to equip-
ment shutoff valve (see Figure 7). Apply
mixture of liquid soap and water to gas
joints. Bubbles forming show a leak.

4.

Correct all leaks at once.

Gas Meter

Equipment Shutoff
Valve

5.

Apply thread sealant to the 1/8" brass
pipe nipple and thread it onto the mani-
fold block. Tighten with a 7/16" wrench.

6.

Slip the air restrictor over the 1/8" pipe
nipple. Apply thread sealant to the male
threads and install the rear burner
nozzle

 

onto the fitting. Tighten with a

9/16" wrench.

7.

Place the grate assembly over the
burner pan. Install the rear burner
bracket onto the grate with the 2 black
Phillips head #10 screws provided. Do
not tighten at this time (see Figure 9).

8.

Install the “U” burner from the left side
with the open end in the front (see Fig-
ure 9). Hold the rear of the burner
higher than the bracket. Slide the burner
over the air restrictor fitting. Lower the
rear of the burner into the slots on the
burner bracket. Install the burner clip
and tighten the nuts and screws.

9.

Install 3/8" flare x 3/8" male pipe el-
bow into the inlet of the manifold block.
Install the pipe plug into the top of the
manifold block. Use thread sealant.

Burner
Inlet
Fitting

Front
Burner

Pipe
Nipple

Air Restrictor

Manifold
Block

Rear Burner Nozzle

Grate

Burner Pan

Burner
Bracket

Burner
Clip

Pipe Elbow

Pipe
Plug

Figure 9 - Installing Burner

Continued

Installation and Gas Connection

1.

Thread the gas supply fitting to the
fireplace gas supply pipe. Use thread
sealant.

2.

Place the burner pan assembly in the
center of the fireplace floor. Make sure
the front of pan faces forward.

3.

Install the flex gas line to the gas sup-
ply fitting. Carefully shape tube to at-
tach to adapter fitting (see Figure 10).

4.

Replace valve cover.

Figure 10 - Connecting Gas to Appliance

Gas
Supply
Fitting

Flex Gas Line

Burner Pan Assembly
(Facing Front of Fireplace)

Figure 7 - Checking Gas Joints

Содержание FVTR18

Страница 1: ...rrect installation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only in a solid fuelburningmasonryorUL127 factory built fireplace con structed of noncombustible material and connected to a working flue See page 7 for minimum flue opening WARNING This is a gas fired app...

Страница 2: ...and fire box must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage 5 You must operate this log set with a fire placescreeninplace Makesurefireplace screen is closed before running log set 6 This log set is designed to be smoke less If logs ever appear to smoke turn off appliance and call a qualifi...

Страница 3: ...ilot kit to use remote accessories with this appliance See Acces sories page 17 LOG SETS Model FTLCR18 log set is for use with ModelFVTR18burnerset ModelFTLCR24 logsetisforusewithModelFVTR24burner set Use these log sets only with their corre sponding burners UNPACKING CAUTION Do not remove the metal data plates from the burner pan The data plates contain im portant product information 1 Remove log...

Страница 4: ...lpreduceheatlossinhomes Homeowners weather strip and caulk around windows and doorstokeepthecoldairoutandthewarmair in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper com bustion and ventilation Exhaustfans fi...

Страница 5: ...raws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maximum the space can support _____________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 95 000 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space ...

Страница 6: ...o adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Ventilation Air From Outdoors Provide extra fre...

Страница 7: ... must be in stalled only in a solid fuel burning fireplace with a working flue and constructed of non combustible material The charts in Figure 4 indicate technical information regarding the installation of your gas log set Please make sure that all of the specifications shown are applicable be fore installation is attempted The fireplace must include a working flue andventingsystemwiththeminimumo...

Страница 8: ...low piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection adjustable crescent wrench or pliers sediment trap tee joint pipe wrench CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to log set If pipe is ...

Страница 9: ...ck Tighten with a 7 16 wrench 6 Slip the air restrictor over the 1 8 pipe nipple Apply thread sealant to the male threads and install the rear burner nozzle onto the fitting Tighten with a 9 16 wrench 7 Place the grate assembly over the burner pan Install the rear burner bracket onto the grate with the 2 black Phillips head 10 screws provided Do not tighten at this time see Figure 9 8 Install the ...

Страница 10: ...front Close Pipe Nipple Gas Control Valve Manifold Block Figure 11 Installing Gas Control Valve Control Rod INSTALLATION Continued 9 Install valve cover to burner pan using screws provided 10 Install thermocouple pilot and ignitor onto valve cover as shown in Figure 14 Use the provided screws 11 Push the control rod extension onto the D shaped control rod through the cen ter hole in the cover 12 I...

Страница 11: ...ve immedi ately Tighten or reassemble the loose connection s using pipe joint com pound until burner system is leak free 4 When the burner is tested and leak free observe the individual tongues of flame on the burner Note The burner design includes more ports on the outside of the bar Make sure that all ports are clear and producing flame evenly across the burner Ifanyportsappearblocked clear them...

Страница 12: ...TOP Fol low the safety information above If you don t smell gas go on to the next step 4 Light a match and lay it on top of the U shaped burner near the edge of the cover on the right side of the pan 5 Slowly turn the gas shutoff valve ON until the burner ignites If the burner doesn t ignite within 10 seconds with the match burning turn the shutoff valve OFF and repeat steps 1 through 4 again WARN...

Страница 13: ...pressed in for five 5 seconds Note You may be running this log set for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 sec onds This will allow air to bleed from the gas system If control knob does not pop up when released contact a qualified service person or gas supplier for repairs 6 With control knob pressed in push down and release ignitor...

Страница 14: ...oking sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is especially true with propane LP gas Burner is excessively noisy Note Themovementandcombustionofgas will create low unavoidable levels of noise Burner flame is too low or too high 1 Contact local natural or propane LP gas company 2 Adju...

Страница 15: ...nce page 17 or replace pilot assembly 5 Hand tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP gas company 3 Replace burner orifice 4 Reconnect leads 1 Adjust pilot flame for approximately 2 blue flame 2 Replace pilot orifice set POSSIBLE CAUSE 1 Ignitor electrode not connected to igni tor cable...

Страница 16: ...at top of page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is common with most log sets If noise is excessive contact qualified ser vice person 1 Open flue to maximum Stop using odor causing products while log set is running...

Страница 17: ...lreplacementpart s call DESA International s Technical Service Department at 1 800 DESA LOG 1 800 337 2564 WhencallingDESAInternational haveready your name your address modelandserialnumbersofyourfireplace how fireplace was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the defec tive part to the factory PARTS NOT UNDER WARRANTY Contact au...

Страница 18: ...18 901846 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN FVTR18 4 19 21 20 22 23 24 25 2 3 8 7 11 10 1 5 6 15 9 14 12 13 26 16 18 5 17 ...

Страница 19: ...064 05 Natural Gas Injector 1 11 901066 01 Brass Air Mixer Natural Gas 1 12 901761 01 1 8 Hex Nipple 1 13 901760 01 Manifold Block 1 14 901751 01 Air Restrictor 1 15 901756 01 Valve Cover 1 16 901056 01 Brass Elbow Flare Fitting 1 17 901058 01 Brass 3 8 FLR x 1 2 FPT Adapter 1 18 101628 01 Gas Line 10 Flex 1 19 901769 02 Ember Bed 1 20 901591 08 Top Log VCR11 FS 1 21 901528 03 Top Log CS 16 FS 1 2...

Страница 20: ...20 901846 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN FVTR24 4 19 23 21 22 20 24 25 2 3 8 7 11 10 1 5 6 15 9 14 12 13 26 16 18 5 17 ...

Страница 21: ...1064 01 Natural Gas Injector 1 11 901066 01 Brass Air Mixer Natural Gas 1 12 901761 01 1 8 Hex Nipple 1 13 901760 01 Manifold Block 1 14 901751 01 Air Restrictor 1 15 901756 01 Valve Cover 1 16 901056 01 Brass Elbow Flare Fitting 1 17 901058 01 Brass 3 8 FLR x 1 2 FPT Adapter 1 18 101628 01 Gas Line 10 Flex 1 19 901769 01 Ember Bed 1 20 901527 05 Top Log CS 12 FS 1 21 901528 03 Top Log CS 16 FS 1 ...

Страница 22: ...________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________...

Страница 23: ...____________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________________________________________________________________________...

Страница 24: ... set will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA TION OF ANY AND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO 2 YEARS ON BURNER SYSTEM AND A LIFETIME ON LOGS FROM THE DATE OF...

Отзывы: