background image

26

107205

DIRECT-VENT FIREPLACE

For more information, visit www.desatech.com

PILOT AND BURNERS

• Remove ember material before cleaning

burners and replace when cleaning is
complete.

• Burner and controls should be cleaned with

compressed air to remove dust, dirt, or lint.

• Use a vacuum cleaner or small, soft bristled

brush to remove excess dust, dirt, or lint.

LOGS

• If you remove logs for cleaning, refer to

Installing Logs, Lava Rock, and Glowing
Embers
, page 23, to properly replace logs.

• Use a vacuum cleaner to remove any car-

bon buildup on logs.

• Replace log(s) if broken. See Replace-

ment Parts on page 30.

• Replace ember material periodically as

needed. See Replacement Parts on page 30.

 WARNING: Only parts sup-

plied by the manufacturer should
be used when replacing broken
or damaged glass door panel (see
Replacement Parts, page 30). This
glass door panel is a complete
unit. No substitute materials may
be used.

CLEANING AND
MAINTENANCE

If glass has been broken, carefully remove
glass door (see Removing/Replacing Glass
Door, 
page 21). Vacuum all glass pieces with
a shop vac.

 CAUTION: Wear gloves and

safety glasses while handling or
removing broken glass. Do not
remove if glass is hot. Keep chil-
dren and pets away from glass.

 WARNING: Do not operate

fireplace with the glass door re-
moved, cracked, or broken.

VENTING SYSTEM

Conduct annual inspection of the venting
system following these guidelines:

1.

Check areas of venting system that are
exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced imme-
diately by a qualified service person.

2.

Remove the vent cap and shine a flash-
light into the vent. Remove any foreign
material.

3.

Check for evidence of excessive con-
densation. Continuous condensation
can cause corrosion of caps, pipes, and
fittings and can be caused by having
excessive lateral runs, too many el-
bows, or exterior portions of the sys-
tem being exposed to cold weather.

4.

Inspect joints to verify that no pipe sec-
tion or fitting has been disturbed and
loosened. Check mechanical supports
such as wall straps for rigidity.

 WARNING: Turn off fireplace

and let cool before cleaning.

 CAUTION: You must keep con-

trol areas, burners, and circulat-
ing air passageways of fireplace
clean. Inspect these areas of fire-
place before each use. Have fire-
place inspected yearly by a quali-
fied service person. Fireplace may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.

 WARNING: Do not use abra-

sive cleaners as this may damage
glass. Use a nonabrasive house-
hold glass cleaner to clean glass.
Do not clean glass when hot.

  WARNING: Handle glass door

panel with care. Do not strike,
slam, or otherwise abuse glass.
Do not operate fireplace with the
glass door removed, cracked, or
broken.

GLASS DOOR

Glass must be cleaned periodically. During
start-up it is normal for condensation to
form on the inside of the glass causing lint,
dust, and other airborne particles to cling to
the glass surface. During initial start-up a
slight film may form on the glass due to
paint curing. The glass should be cleaned
several times with a non-ammonia, non-
abrasive household cleaner and warm water
after the first two weeks of operation. There-
after, clean the glass two or three times
during each heating season, depending on
the usage and circumstances present. Refer
to Removing/Replacing Glass Door on page
21 of this manual when removing glass door
for cleaning.

 CAUTION: Do not vacuum if

pieces are hot.

Use only the glass door replacement in-
tended for this fireplace (see Replacement
Parts
, page 30 for detail on ordering). No
substitutions may be made. See Removing/
Replacing Glass Door
, page 21  for instruc-
tions for replacing glass door.

Содержание DVFE34

Страница 1: ...ioncon sult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by state or local codes WARNING If...

Страница 2: ...e indicated on fire place nameplate 14 This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code AN...

Страница 3: ...ricity to operate Figure 1 FMI Direct Vent Fireplace DVFE Series Glass Door Assembly Blower Adjustment Optional Installation ON OFF Remote Switch Optional Installation Valve Pilot Assembly Log Set Gra...

Страница 4: ...34 5 8 for drywall facing Must maintain a minimum 1 clearance to combustibles 34 3 4 34 1 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for the fire...

Страница 5: ...ted otherwise Combustible material may be flush with the top front of fireplace with a maxi mum thickness of 3 4 Do not recess venting terminals into a wall or siding If exterior wall is vinyl you mus...

Страница 6: ...rance to a mechanical air supply inlet 72 inches 1829mm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porc...

Страница 7: ...Termination Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Terminat...

Страница 8: ...d vent pipes and fittings have spe cial twist lock connections Assemble the desired combination of pipe and el bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lo...

Страница 9: ...ng mastic around the outside edge of the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of...

Страница 10: ...w 67 min 60 max 79 min 84 max 96 min 20 max Note This configuration for use with corner installation Rigid Vent Pipe Horizontal Termination Configurations Figures 16 through 19 show different con figu...

Страница 11: ...Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 18 Horizontal Termination Configuration for Rigid Venting Usin...

Страница 12: ...ng members Note Pay special attention to these installation instruc tions for required clearances air space to combustibles when passing through ceilings walls roofs enclosures attic rafters etc Do no...

Страница 13: ...Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold the resulting fl...

Страница 14: ...un VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 26 Vertical Rigid Ve...

Страница 15: ...G KITS AND COMPONENTS FMI Rigid Venting Number Description FD30 30 Starter Adapter 65 8 to7 6 per box FD60 60 Starter Adaptor 65 8 to7 6 per box F7030 7 to 12 Adjustable pipe length 6 per box D1031 7...

Страница 16: ...un system s circulating blower while using fireplace This will help circulate the heat through out the house In the event of a power outage you can use this fireplace as a heat source WARNING Aqualifi...

Страница 17: ...rough the right side see Figure 32 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system...

Страница 18: ...acceptable alternative to test gauge connection Pur chase the CSA design certified equipment shutoff valve from your retailer WARNING A qualified ser vice person must connect fire place to gas supply...

Страница 19: ...s supply Check re connected fittings for leaks CHECKING GAS CONNECTIONS WARNING Test all gas pip ing and connections for leaks after installing or servicing Cor rect all leaks at once WARNING Neveruse...

Страница 20: ...utoff valve see Fig ure 36 2 Open propane LP supply tank valve for propane LP fireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace...

Страница 21: ...best fits your needs when installing this accessory The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off The wall switch is to be connected...

Страница 22: ...he same method described in step 3 6 Slide the right retainer bracket against the right side brick panel Loosely se cure the bracket screw This secures the right side brick panel 7 Install rear brick...

Страница 23: ...og 4 right piece onto the front right part of the grate making sure the notches fit over the prong of the grate see Figure 48 6 Place lava rock along sides and front of inside of firebox bottom It is...

Страница 24: ...n see Figure 50 Do not force 6 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation in column one If you don t...

Страница 25: ...H This wall switch works just like the con ventional light switch Flip the switch up for on and down for off Note Make sure that this switch is not in apositiontobemistakenforalightswitch This may res...

Страница 26: ...osion of caps pipes and fittings and can be caused by having excessive lateral runs too many el bows or exterior portions of the sys tem being exposed to cold weather 4 Inspect joints to verify that n...

Страница 27: ...ating 1 Pilot flame may be too low causing safety pilot to drop out 2 Vent may be blocked or restricted REMEDY 1 Check to see if you have gas supply and that the equipment shutoff valve is opened 2 Re...

Страница 28: ...a few hours of operation 1 Operate burner until air is removed from line Have gas line checked by local natural gas company 2 Clean burner see Cleaning and Maintenance page 26 or replace burner orifi...

Страница 29: ...ning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor ev...

Страница 30: ...PARTS UNDER WARRANTY Contact authorized retailers of this product If they can not supply original replacement part s call DESA International s Technical Service Department at 1 800 DESA LOG 1 800 337...

Страница 31: ...ition Piezo Manifold Pressure 3 5 w c Minimum Inlet Supply Pressure 4 5 w c Dimension Inches mm HxWxD Fireplace Actual size of firebox Measurements do not 32 3 16 x 34 3 8 x 18 1 2 include nailing fla...

Страница 32: ...visit www desatech com 47 1 2 3 4 6 6 35 5 5 5 11 Included in Hardware Pack 7 7 8 10 9 12 13 14 15 16 25 26 27 28 29 31 1 31 4 31 2 31 3 33 32 32 34 46 36 37 39 38 42 40 41 6 44 43 48 20 23 21 22 24...

Страница 33: ...sembly SIT Electronic 1 19 107443 01 Pilot Mounting Bracket 1 20 14104 Plug 2 Prong 1 21 107222 01 Transformer 24 VAC 1 22 107221 01 Ignition Module 1 23 23416 Mounting Board Electronic 1 24 104514 01...

Страница 34: ...on fireplace BRICK LINER D8037A Not Shown This brick liner adds a touch of style to your direct ventfireplaceandcomeswitheasyto follow instructions for installation ON OFF WALL MOUNT SWITCH GWMS2 Not...

Страница 35: ..._________________________________________ _______________________________________________________________________________________________ ______________________________________________________________...

Страница 36: ...tive heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPR...

Отзывы: