FMI DVF36 Скачать руководство пользователя страница 2

www.fmiproducts.com

56131J

2

SAFETy

 

WARNING:  Improper 

installation,  adjustment, 

alteration,  service  or 

maintenance  can  cause 

injury  or  property  dam

-

age. Refer to this manual 

for  correct  installation 

and  operational  proce

-

dures. For assistance or 

additional  information 

consult  a  qualified  in

-

staller, service agency or 

the gas supplier.

This appliance may be in

-

stalled in an aftermarket,* 

permanently  located, 

manufactured  (mobile) 

home, where not prohib

-

ited by local codes.
This appliance is only for 

use  with  the  type  of  gas 

indicated  on  the  rating 

plate.  This  appliance  is 

not  convertible  for  use 

with  other  gases,  unless 

a certified kit is used.

* Aftermarket: Completion of sale, not for 

purpose of resale, from the manufacturer

This direct-vent gas fire

-

place  heater  series  is 

intended  for  use  with 

natural  or  propane/LP 

gas only. Do not attempt 

to burn any solid fuels in 

these appliances.

State  of  Massachusetts: 

The  installation  must 

be  made  by  a  licensed 

plumber  or  gas  fitter  in 

the  Commonwealth  of 

Massachusetts.

 WARNING: This product con

-

tains and/or generates chemicals 

known to the State of California 

to cause cancer or birth defects 

or other reproductive harm.

IMPORTANT: Check local codes 

before installing this fireplace.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before trying to assemble, op

-

erate  or  service  this  fireplace. 

Improper  use  of  this  fireplace 

can  cause  serious  injury  or 

death  from  burns,  fire,  explo

-

sion, electrical shock and carbon 

monoxide poisoning.

TAbLE OF CONTENTS

Safety .................................................................. 2

Dimensions .......................................................... 5

Pre-Installation Preparation ................................. 6

General Venting ................................................... 9

Venting Installation..............................................11

Fireplace Installation.......................................... 21

Pilot/Electrode Assembly Adjustment ................ 26

Burner Flame Adjustment .................................. 26

Operating Guidelines and Maintenance ............ 27

Operation ........................................................... 28

Specifications

 .................................................... 30

Troubleshooting ................................................. 31

Wiring Diagrams ................................................ 33

Service Hints ..................................................... 33

Technical Service............................................... 33

Parts and Accessories ....................................... 34

Replacement Parts ............................................ 34

Warranty ..............................................Back Cover

Содержание DVF36

Страница 1: ...tch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Inst...

Страница 2: ...ny solid fuels in these appliances State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts WARNING Thisproductcon tainsand orgener...

Страница 3: ...Do not modify this fireplace under any circum stances Any parts removed for servicingmustbereplacedprior to operating fireplace DANGER Carbonmonoxide poisoning may lead to death Before beginning the...

Страница 4: ...ormance problems do not use propane LP fuel tank of less than 100 lbs capacity 2 If you smell gas shut off gas supply do not try to light any appliance do not touch any electrical switch do not use an...

Страница 5: ...1 2 3 22 5 8 34 3 4 TOP VIEW Left Side Right Side Front Back 24 1115 16 101 2 11 2 11 2 111 8 Figure 1 Peninsula Dimensions Figure 2 See Thru Dimensions 10 Do not operate fireplace with glass door re...

Страница 6: ...rements Determine the safest and most efficient loca tion for your FMI PRODUCTS LLC direct vent fireplace Make sure that rafters and wall studs are not in the way of the venting system Choose a locati...

Страница 7: ...Figure 5 Minimum Clearances See Thru Shown Combustible Material Drywall 2 x 4 Stud Minimum 1 Clearance from Side Only for See Thru Framing Once final location has been determined observing clearances...

Страница 8: ...n 10 Square Min Figure 12 Rough Opening for Installing Exterior Vent Terminal Vertical Height Depends on Installation 26 3 8 Horizontal Length Depends on Installation 90o Elbow 45o Elbow Figure 13 Ven...

Страница 9: ...1 also known as NFPA 54 These models are approved for use with FMI PRODUCTS LLC 5 8 Series rigid type direct vent pipe as supplied by FMI PROD UCTS LLC or with approved types of flexible vent pipe no...

Страница 10: ...US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L...

Страница 11: ...istance from fireplace flue outlet to ceiling Add ceiling thickness vertical rise in an attic or second story and allow for sufficient vent height above roof line You may use one or two 90 elbows in t...

Страница 12: ...ing codes Note When installing in a chase you should insulate the chase as you would the outside walls of your home This is especially im portant in cold climates Minimum clearance between vent pipes...

Страница 13: ...quare hole through combustible exterior wall 8 1 2 diameter hole if non combustible Frame as necessary Figure 17 Vent Pipe Connections Male Slots Female Locking Lugs Rigid Vent Pipe 4 Three types of v...

Страница 14: ...on at unit is tight and does not come loose before unit is nailed to framing Square vent or long vent configuration Vent pipe must be manipulated at outer end to make final connection Manually secure...

Страница 15: ...is not to be used with a vertical termination 1 Determine route your vertical venting will take If ceiling joists roof rafters or other framing will obstruct venting system consider an offset see Figu...

Страница 16: ...g lumber the same size as ceiling joists If area above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insulation from falling into required clearance space...

Страница 17: ...e If vent pipe passes through any oc cupied areas above the first floor including storage spaces and closets you must enclose pipe You may frame and sheetrock enclosure with standard construction mate...

Страница 18: ...nting Configuration Using Two 90 Elbows Venting Installation Continued Vertical Termination Configurations Figures 29 through 32 show four different configurations for vertical termination These minim...

Страница 19: ...e Galvanized P58 24 24 Section Double Wall Pipe Galvanized P58 12 12 Section Double Wall Pipe Galvanized P58 6 6 Section Double Wall Pipe Gal vanized High altitude installation Your FMI PRODUCTS LLC d...

Страница 20: ...F 58 12 Roof Flashing 6 12 to 12 12 Pitch Galvanized S 58 Vinyl Siding Standoff Galvanized VT 58 Vertical Round Termination Gal vanized HHT 58 High Wind Round Horizontal Ter mination Kit Galvanized HT...

Страница 21: ...e and is located on the lower right side of appliance see Figure 37 page 22 The variable speed controller is mounted on a magnetic base and may be positioned anywhere within an accessible distance beh...

Страница 22: ...re 37 Connecting Blower Accessory to Power Supply For Optional Fan Kit From Blower Assembly 4 Connect white wire to control valve ter minal TH and red wire to TPTH Move remote select switch to the REM...

Страница 23: ...ebox and surround of fireplace see Figure 43 Fireplace Installation Continued IMPORTANT The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any...

Страница 24: ...as control valve is accessible from lower control compartment Two pressure taps are provided on gas control valve for a pressure gauge connection see Figure 44 O F F P I L O T ON L O HI P ILOT E A 16A...

Страница 25: ...ce twig E across top of logs B a shown in Figure 51 11 When finished installing logs close glass door Make certain safety door switch is fully pressed by door frame before secur ing four 4 spring load...

Страница 26: ...proper clearances are observed see Clearances page 6 IMPORTANT Louvered openings must not be obstructed and upper and lower panels must remain removable for Fireplace Installation Continued servicing...

Страница 27: ...ng of burner and pilot as sembly In cleaning take care not to alter pilot or burner location Be sure appliance is cool before each maintenance session CAUTION Theapplianceand logs can get very hot Han...

Страница 28: ...ure seam in gasket is placed in the down position 4 Replace screen assembly and top and bottom louvers FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a f...

Страница 29: ...TPTH TP TH Gas Control Knob Flame Adjustment Knob Position Indicator Figure 59 Millivolt Control Valve Figure 60 Pilot Thermopile Pilot Burner Piezo Ignitor Thermocouple Operation Continued TO TURN O...

Страница 30: ...PEA A V DVF36TSTA A AND V DVF36TSTEA A Input Rating 35 000 23 300 Btu Hr Fuel Natural Gas Manifold Pressure 3 5 W C Minimum Supply Pressure 4 5 W C Maximum Supply Pressure 10 5 W C Orifice Size 0 4500...

Страница 31: ...echnician replace pilot line 7 Replace control valve see Replacement Parts and Ac cesssories page 34 8 Tighten thermocouple or replace 1 Check wiring connection Refer to Wiring Diagrams page 33 1 Chec...

Страница 32: ...hoses Con sult pipe fitter or plumber 2 Repeat lighting procedure several times to purge air from lines If unit will still not light contact a qualified ser vice and repair technician 3 Remove debris...

Страница 33: ...STEP DOWN 120V AC 24V AC OFF WALL SWITCH SUPPLIED ON IGNITER ASSEMBLY D V2 G N L1 IND IGNITION CONTROL MODULE TS S1 SW V1 P GND J BOX RECEPTACLE OPTIONAL CONTROL REMOTE GRN BLK WHT GRN NOT SUPPLIED I...

Страница 34: ...tude 117370 01 Have a qualified technician replace part Orifice Natural 23103 Propane LP 23104 Electronic GAS VALVE Natural 14428 Propane LP 14429 Have a qualified technician replace part Ignitor ASSE...

Страница 35: ...45 Refractory Pieces Front Bottom 25854 Left Right Bottom 25856 Rear 25855 Front Bottom Left Right Bottom Rear For Peninsula and See Thru Piezo Ignitor 14261 Grate 11184 Parts and Accessories Continue...

Страница 36: ...roduct and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mater...

Отзывы: